Assembly Instruction
KS2 / KS2 T
WIN
E
LECTRICAL
CONNECTION
CONFIGURED
WITH
M-COM
Individual expansion:
Multi-drive operation with M-COM and locking drive
Multi-drive operation: Drive „Set A“ with M-COM and locking drive
230V / 24V
24V
I
NSTALLATION
STEP
9:
E
LECTRIC
CONNECTION
Optional:
second cable
Optional:
second cable
Antrieb 230V R
Antrieb 24V L (K)
M-COM
locking drive
24V DC, non-halogen
ca. 3m, 3 x 0,5 mm
2
24V DC, non-halogen
ca. 3m, 3 x 0,5 mm
2
24V DC, non-halogen
ca. 3m, 3 x 0,5 mm
2
A maximum of
three single-drive
and
one locking drive
are possible.
Optional: Second drive-cable.
Confi guration is done by
M-COM
.
07
N
OTE
N
OTE
M-COM
always connect to the
24V
side!
BN = brown
BU = blue
WH = white
BN = brown
BU = blue
WH = white
24V
Optional:
second cable
site-supplied
site-supplied
site-supplied
locking drive
M-COM
24V DC, non-halogen
ca. 3m, 3 x 0,5 mm
2
24V
voltage
output
24V
voltage
input
230V
junction box
site-supplied
Drive „Set A“
factory-confi gured set.
includes:
Master
:
KS2 S12 230V AC R with voltage output 24V DC
Slave
:
KS2 S12 24V DC R with conection cable on the motor side
OPTIONS:
Programmable special functions and sequence control
with locking drives.
Confi guration is done by
M-COM
.
either
detail
Drive:
Set A
Individual
expansion
BN
BU
WH
polarity
reversal