23
Assembly Instruction
FTA 600
Multi-drive operation with master and slave
I
NSTALLATION
STEP
6:
Multi-drive operation with M-COM
+
+
-
-
+
+
-
-
BN
BN
BU
BU
WH
WH
AK
AK
!
Connection assignment
BN
VT
WH
GN
BU
AK
M-COM
BN
+
-
BU
-
+
!
06
AK
AK
Make sure when establishing the connection
that there is no voltage at the terminals!
Unused wires must be safely insulated!
The running direction of the drive may be changed by
interchanging (polarity reversal) the wires
„BN – (brown)“
-
„BU – (blue)“
.
Direction of travel
OPEN
CLOSE
Polarity reversal
+
+
-
-
Wire colour coding
Wire colour coding
DIN IEC 757
blake
BK
white
WH
brown
BN
blue
BU
green / yellow
GN / YE
green
GN
violet
VT
grey
GY
WH
is used for communication
(in systems with synchronized
multi-drive operation)
Standard
CLOSE
/ Optional
OPEN
:
contact max. 24 V, 500 mA
(min. 10mA)
E
LECTRIC
CONNECTION
E
LECTRIC
CONNECTION
+
+
-
-
from control unit
from control unit
master
drive 1
slave
drive 2
24 V DC control
24 V DC control
junction box
site-supplied
junction box
site-supplied
WH
connection.
Drives do not work, if not connected.
WH
connection.
Drives do not work, if not connected.
polarity
reversal
polarity
reversal
The programming of the drives in multi-drive occurs at factory or on
site with UniPC
is used for communication, with synchronized multi-drive
operation.
is used for communication, with synchronized multi-drive
operation.
1 to 4 drives and max. 2 locking drives are possible.
1 to 4 drives and max. 2 locking drives are possible.