Aumuller FTA600 DF Assembly And Commissioning Instructions Download Page 10

10

Assembly Instruction

 FTA 600 

D

ATA

 

SHEET

D

ATA

 

SHEET

 FTA600 DF S12 24V DC

ORDER DATA

s [DEG]

L [mm]

Version

Finish

PU / pcs.

Part.-No.

0˚ – 93˚

421

FTA600 DF S12 24V

E6/C-0

1

524145

ACCESSORIES

PU / pcs.

Part.-No.

K103

 Frame bracket FTA600 DF

1

524172

OPTIONS

Special model

PU / pcs.

Part.-No.

Drive housing painted/powder coated in other RAL colours

Specify at order stage:

516004

Microprocessor programming S12

Electrical st

roke reduction

1

524190

Special functions

1

524180

Optional accessories

PU / pcs.

Part.-No.

M-COM Comm. module for synchronised multi-drive systems

1

524177

TECHNICAL DATA

U

N

Rated voltage

24V DC (± 20 %), max. 2 Vpp

I

N

Rated current

0,8 A

I

A

Cut-off current

1,4 A

P

N

Rated power

20 W

ED

Duty cycle

30 %  (ON: 3 min. / OFF: 7 min.)

Protection rating

IP 32

Ambient temperature range

-5 °C ... +75 °C

M

A

Torque OPEN

215 Nm (600 N) 

M

Z

Torque CLOSE

 

215 Nm (600 N)

F

H

Pullout force 

3000 N (fastening depended)

Lever arm

aluminium (RAL9006) 

Connecting cable with plug

non-halogen, grey  5 x 0,5 mm², ~ 3 m

t

Running time (0° - 90°)

 45 s (2,0°/s)      

 45 s (2,0°/s)

s

Window-opening angel

0° – 93° (± 5 %) 

L

Length

421 mm

Potential free contact

max. 24V DC / 0,5A programmable

       

   Sound pressure level A

 70 dB (A)

 

Application: natural ventilation, SHEV, ferralux®-NSHEV

 

Mainly for opening and closing of side-hung inward opening windows 

 

Internal intelligent cut-off switch S12

 

Programmable contact for door opener

 

Unitary plug-solution for all 

A

UMÜLLER

 chain drives and 

A

UMÜLLER

 folding arm drives

Options

 

Programmable special functions

 

M-COM for automatic synchronised run of multi drive systems and automatic sequence 

 

control with FV locking drives (S3/S12 SW V2)

 

Various customised programmings on request

24 V DC

ø5,5 (4x)

6,5

L

 = 421

       381

40

20

56

24

16

15

86

M10

max. 93°

02

Summary of Contents for FTA600 DF

Page 1: ...FTA600 R FTA600 DF FTA600 GF FOLDING ARM DRIVES according to Machinery Directive 2006 42 EC annex VI Assembly and Commissioning Instructions...

Page 2: ...ON STEP 4B FTA600 R Hinge side mounting inward opening door INSTALLATION STEP 4C FTA600 DF Hinge side mounting inward opening side hung window INSTALLATION STEP 4D FTA600 GF Opposite hinge side mounti...

Page 3: ...G AND SAFETY SYMBOLS IN THESE IN STRUCTIONS The symbols used in the instructions shall be strictly observed and have the following meaning Caution Warning Danger due to electric current Caution Warnin...

Page 4: ...0 mm by a simultaneous speed of 15 mm s at the HSK in closing direction Application as NSHEV natural smoke and heat exhaust ventilators for ventilation without dual function for ventilation in accorda...

Page 5: ...oor ZAA 20 1 Opening at HSK 200 mm and Speed at HSK CLOSE 15 mm s OPEN 50 mm s 20 ZAA 2 Yes Yes No No Risk covered by Declaration of Conformity for window drives Observe danger at NSK 2 5 m above floo...

Page 6: ...connection assignment the electrical supply data see machine plate and performance limits see technical data as well as the mounting and installation instructions of the drive must be strictly observe...

Page 7: ...h a trial run It shall be ensured that drive and casement are set correctly and that security systems if available are functioning properly After the installation of the system is completed the end us...

Page 8: ...ive shall only be operated with control devices from the same manufacturer There is no liability warranty or customer service if third party parts are used Exclusively original replacement parts of th...

Page 9: ...ir intlets Internal intelligent cut off switch S12 Programmable contact for door opener Unitary plug solution for all AUM LLER chain drives and AUM LLER folding arm drives Options Programmable special...

Page 10: ...temperature range 5 C 75 C MA Torque OPEN 215 Nm 600 N MZ Torque CLOSE 215 Nm 600 N FH Pullout force 3000 N fastening depended Lever arm aluminium RAL9006 Connecting cable with plug non halogen grey...

Page 11: ...gent cut off switch S12 Programmable contact for door opener Unitary plug solution for all AUM LLER chain drives and AUM LLER folding arm drives Options Programmable special functions M COM for automa...

Page 12: ...losing edges Space on the frame above min 56 max 106 mm Space on the frame above min 40 mm Space on the frame above min 48 mm Space on the frame min 60 mm on the casement min 40 mm door width 1200 mm...

Page 13: ...ins spind les of the drives must be extendable or retractable easily The casement must run smoothly and the weight must be in balance The test procedure of drives may only be performed on a non slip a...

Page 14: ...llowing conditions must be fulfilled for the instal lation of the drives so they can be properly assembled with other parts and constructed to a complete machine at the window without impairing the sa...

Page 15: ...profile depth PT and door hinge dimension B 05 MOUNTING FTA600 R DRILL HOLES ACCORDING TO MOUNTING VARIANTS FTA600 R OPPOSITE HINGE SIDE MOUNTING OUTWARD OPENING DOOR INSTALLATION STEP 3 INSTALLATION...

Page 16: ...IDE MOUNTING INWARD OPENING DOOR 05 INSTALLATION STEP 4B MOUNTING FTA600 R 260 400 422 5 5 x8 408 M5 x4 50 20 5 24 40 4 11 22 33 4 1x Angle L 422 50 x 40 x 4 1x Angle L 100 50 x 75 x 5 with slots 1x A...

Page 17: ...R FTA600 R Ensure that the role of the folding arm drive FTA600 R when opening and closing is based on the angle K88 K88 K88 K88 door leaf door frame 1 2 3 Space A A View from inside FTA600 R M5 105 5...

Page 18: ...5 6 8 35 30 6 6 20 6 5 6 9 70 130 130 408 70 24 22 11 33 M4 M5 RA 1 FTA600 DF 9 05 MOUNTING FTA600 DF 1x Angle L 422 50 x 40 x 4 1x Bolt 14 x 57 x M10 1x Lever arm 14 x 12 x 30 1x Eyebolt M8 1x Caseme...

Page 19: ...mm 81 15 mm 81 10 mm 79 0 mm 77 10 mm 76 20 mm 75 30 mm 05 MOUNTING FTA600 DF 36 47 10 40 20 35 25 X B X X 4 400 356 24 35 13 6 4 40 2 20 17 35 X X 13 5 10 X 4 X X 400 386 24 35 13 6 13 5 1 40 0 2 20...

Page 20: ...e angle of frame bracket K104 at the frame M5 Fasten folding arm drive FTA600 GF on the angle with the screws Fit slide rail with screws M5 at the casement Using the screws and lock washers and mount...

Page 21: ...F 10 10 11 11 Insert the circlip for stabilization in the drill hole Push bolt in the connector Insert this module in slide rail Using the screw and mount the drive arm of the folding arm drive FTA600...

Page 22: ...A FL BD BD AK FL Cable crossover without protective cable hose Cable crossover with protective cable hose Connection cable routing on the hinge side Make sure that during opening or closing procedure...

Page 23: ...grey GY WH is used for communication in systems with synchronized multi drive operation Standard CLOSE Optional OPEN contact max 24 V 500 mA min 10mA ELECTRIC CONNECTION ELECTRIC CONNECTION from contr...

Page 24: ...the housing cover with the both screws Locking hooks at the housing cover prevent withdrawal of the plug under tensile load Five terminals to 1 5 mm2 The performances especially the fire be havior of...

Page 25: ...acket 0 C 70 C 45 x 17 x 6 mm 3 wires 0 5 mm x 50 mm Feature Equipment printed circuit board with connecting wires for in tegration in site supplied junction box Cable junction box for renewal Order n...

Page 26: ...accessibility Ensure expansion possibilities of the drive and the drive cable Consider the cable length of drives Operation of the power operated window When operating the power operated window safety...

Page 27: ...diness must be checked regularly Frequent inspection of the system for imbalance and signs of wear or damages of cables and fastening elements must be performed During maintenance contaminations must...

Page 28: ...s to the country in which the product has been acquired The warranty includes material and manufacturing defects incurred during normal use The warranty period for delivered material is twelve months...

Page 29: ...29 Assembly Instruction FTA600 CERTIFICATES 08...

Page 30: ...30 Assembly Instruction FTA600 CERTIFICATES 08...

Page 31: ...ensure that the data and information are as correct and up to date as possible we still cannot guarantee that they are free from mistakes and errors All information and data contained in this document...

Page 32: ...n Tel 49 8271 8185 0 Fax 49 8271 8185 250 info aumueller gmbh de 9000017000_V0 1_KW05 14 www aumueller gmbh de AUM LLER AUMATIC GMBH Gemeindewald 11 86672 Thierhaupten Tel 49 8271 8185 0 Fax 49 8271 8...

Reviews: