![Aumuller FTA600 DF Assembly And Commissioning Instructions Download Page 15](http://html1.mh-extra.com/html/aumuller/fta600-df/fta600-df_assembly-and-commissioning-instructions_3016560015.webp)
15
Assembly Instruction
FTA 600
Determine fastenings.
Produce drill holes with appropriate cross-section.
For the mounting dimensions please refer to the
following hole layout drawings or project-specifi
c
documents and drawings.
Secure fasteners against loosening; e.g. by applying
removable thread-locking compound such as “Loctite”.
Carefully clear away drilling swarfs to prevent
seals from being damaged.
Avoid surface scratches, for example by using
masking tape.
!
!
Make sure they are parallel to door frame.
Fasten folding arm drive
FTA600 R
with screws
(M5)
on the door frame.
Measure depending on the opening angle „
α
~90°“,
profi le depth „PT“ and door hinge dimension „B“
05
M
OUNTING
FTA600 R
D
RILL
HOLES
ACCORDING
TO
MOUNTING
VARIANTS
FTA600 R - O
PPOSITE
HINGE
SIDE
MOUNTING
-
OUTWARD
OPENING
DOOR
I
NSTALLATION
STEP
3:
I
NSTALLATION
STEP
4
A
:
93°
3
Į
~
90°
408
X
B
PT
inside
outside
P
ATTERN
A - A
Ensure that the role of the folding arm drive
FTA600 R
- when opening and closing - is based on the door!
Optionally, use a door closer
!
FTA600 R
door leaf
door frame
A
A
B
B
View
from inside
door
24
16
M5
59
81
99
102
40
3
FTA600 R
P
ATTERN
B - B
door frame
door leaf
space
„X“
„B“
„PT“
Opening angel „
α
“
~
90°
80 mm
22 mm
40 mm
90 mm
22 mm
50 mm
100 mm
22 mm
60 mm
105 mm
22 mm
65 mm
110 mm
22 mm
70 mm
115 mm
22 mm
75 mm
120 mm
22 mm
80 mm
90 mm
36 mm
40 mm
100 mm
36 mm
50 mm
105 mm
36 mm
60 mm
110 mm
36 mm
65 mm
115 mm
36 mm
70 mm
120 mm
36 mm
75 mm
125 mm
36 mm
80 mm