9
Assembly Instruction
FVU
D
ata
s
heet
Application: natural ventilation, RWA, ferralux®-NRWG
Surface or concealed mounting inside profiles
Locking plate (8 mm) or optional locking plate (6 mm)
Locking position selectable
Manual unlocking mechanism
Running direction adjustable
Options
Special functions programmable
ORDER DATA
s [mm]
L [mm]
Version
Finish
PU / pcs.
Part.-No.
18
415
FVUI
E6/C-0
1
515910
D
ata
sheet
FVUi
M-COM suitable internal Control Electronics and sequence control for drives S3 / S12
Star wiring
Current of the drives does not run over FVUI
Sequence control via communication wire
16
26
5,5
387,5
s = 18
±1
303
415
26
(66,5)
11
235
37
63
8
Running direction adjustable
by using of a push button
(OPEN position = factory settings)
MOUNTING POSSIBILITIES OF THE LOCKING PLATE
Locking plate is included separately
(optional installation possible)
Locking plate
Locking plate
Mounting example
"Version - 2"
Mounting example
"Version - 1"
(Manual unlocking mechanism)
Factory settings
TECHNICAL DATA
U
N
Rated voltage
24V DC (19 V ... 28 V)
I
N
Rated current
0,6 A
I
A
Cut-off current
~ 1,0 A
P
N
Rated power
15 W
DC
Duty cycle
5 cycles (ED 30 % - ON: 3 min. / OFF: 7 min.)
Protection rating
IP 32
Ambient temperature range
-5 °C ... +60 °C
F
A
Pushing force max.
~ 600 N
F
L
Breakout force max.
~ 1000 N
F
H
Pullout force max.
1.500 N
t
Running time
~ 5,0 s
s
Stroke
~ 18 mm (± 1)
Connecting cable
non-halogen, grey 6,2 mm,
3 x 0,5 mm², ~ 3 m
Coupling adapter
die-cast zinc
Housing
aluminium (E6/C-O)
L, (WxH)
Dimensions
L = 415 mm, 26 x 26 mm (W x H)
Sound pressure level
≤ 70 dB (A)
is included separately
is included separately
ACCESSORIES
(separate order)
Locking plate B31
(optional)
Part.-No.: 515911
Material:
die-cast zinc
Locking plate 6 mm
due to limited space
6
17,5
11
37
30
(unlock
ed)
OPEN
CLOSE
(lock
ed)
FVUI
02
Summary of Contents for 515910