11
Assembly Instruction
FVU
D
ata
s
heet
D
ata
sheet
FVUB L
Application: natural ventilation, RWA, ferralux®-NRWG
Surface mounting on the on the main / side closing edge (HSK / NSK)
of the window frame profiles (RM) of inward opening windows
Required mounting space 28 mm
Locking drives for existing locking bar
Running direction adjustable
Options
Coupling adapter customizable for project-specific / profile-specific demands
16
26
5,5
387,5
s = 18
±1
303
415
2
16
26
63
24
40
TECHNICAL DATA
U
N
Rated voltage
24V DC (19 V ... 28 V)
I
N
Rated current
0,6 A
I
A
Cut-off current
~ 1,0 A
P
N
Rated power
15 W
DC
Duty cycle
5 cycles (ED 30 % - ON: 3 min. / OFF: 7 min.)
Protection rating
IP 32
Ambient temperature range
-5 °C ... +60 °C
F
A
Pushing force max.
~ 600 N
F
L
Breakout force max.
~ 1000 N
F
H
Pullout force max.
1.500 N
t
Running time
~ 5,0 s
s
Stroke
~ 18 mm (± 1)
Connecting cable
non-halogen, grey 6,2 mm,
3 x 0,5 mm², ~ 3 m
Coupling adapter
stainless steel
Housing
aluminium (E6/C-O)
L, (WxH)
Dimensions
L = 415 mm, 26 x 26 mm (W x H)
Sound pressure level
≤ 70 dB (A)
M-COM suitable internal Control Electronics and sequence control for drives S3 / S12
Star wiring
Current of the drives does not run over FVUB
Sequence control via communication wire
ORDER DATA
s [mm]
L [mm]
Version
Finish
PU / pcs.
Part.-No.
18
415
FVUB L
E6/C-0
1
515940
MOUNTED DIMENSIONS OF THE COUPLING ADAPTER
Coupling adapter is included separately
Accessories: Coupling adapter (separate order)
11
25
30
22
40
11
19
24
16
40
Running direction adjustable
by using of a push button
(OPEN position = factory settings)
Accessories
optional order
Part.-No. 515931
Factory settings
(
left
)
(unlock
ed)
OPEN
CLOSE
(lock
ed)
FVUB
additionally order
Coupling adapter
Coupling adapter
is included separately
02
Summary of Contents for 515910
Page 46: ...46 Assembly Instruction FVU 08...