Connect Devices to the Door/Switching Module
29
If you do not need all the door key inputs for the door ringing, you are
able to use the door key inputs as alarm inputs. In order to obtain one
alarm input, the door key input has to be reconfigured with the configu-
ration program COMset.
An alarm input can be connected to an alarm indicator output like in
. You will get more details in the
In the default factory settings the available relays are configured for
door functions. Changes are possible with COMset. Which configura-
tion options for the relays are available with the PBX or which operation
modes are selectable for the relays are shown in the following tables. A
more detailed description of the configuration options can be learned in
the
chapter Configure the COMpact TS Module on page 46
The relays no. 1/4 offer the make contact each, the relays no. 2/5 a
make contact with protection circuit (100 nF, 220
액
) and the relays no.
3/6 offer a make and break contact.
The COMpact TS Module offers no supply voltage on the clamps that
means the supply of the connected units has to be made by an external
voltage.
Pay attention to the maximum rating of the relay contacts (30 V AC/1 A)
that are absolutely not suited for mains-operated devices. Due to this
fact an interconnecting of a mains relay is necessary.
Connect an Alarm System
Pic. 33: Alarm
Connection of external Devices to the switching Relays
Relay no.
Operation Mode: Door Function
1/4
Talking to the door when picking up the receiver
2/5
Door opening for 1-99 sec after dialling a number during a door talk
3/6
Simultaneous switching on e.g. floor light for 1-99 min.
Relay no.
Operation Mode: Alarm Function
1/4 and 3/6
Switching on e.g. a siren for 1-99 sec when activating the alarm contact
2/5
Switching on e.g. a signal light for 1-99 min. when activating the alarm contact
Relay no.
Operation Mode: Music Function
1/4, 2/5 and 3/6
Switching on e.g. a CD player for 1-99 min. as soon as the Music on Hold is needed (during transfer, Query etc.
Relay no.
Operation mode: Universal switching Relay
1/4, 2/5 and 3/6
Switching on e.g. a fax machine (different switching options on):
1st Switched on during the 1st to 6th PBX configuration (during day, night, at noon etc.)
2nd Remote switching from an internal telephone
3rd Remote switching from an external telephone
4th Switch on for 1-99 min. as soon as a defined internal subscriber of the PBX is called (PC relay)
Relay no.
Operation mode: Announcement Function
1/4, 2/5 and 3/6
Switching on of e.g. a loudspeaker when the announcement output (audio output) is called.