INSTALLER
7 & 11kW HRC
70
HIGH TEMPERATURE HEAT PUMP
MANUAL
-
65
Hydraulic schematic diagram -1 RADIATOR C PERMANENT POOL-
HPCP
= circulator pump for Heat Pump circuit
C1CP
= circulator pump for pool
C2CP
= circulator pump for heating circuit
FRM
= Heat Pump circuit fl ow rate monitor
SV
= 3-bar safety valve
A
= Air valve
PTS =
HRC
70
Pilot temperature sensor (or outgoing water
sensor OW)
AQS
= 110°C safety aquastat with manual reset
WP
= water pressure sensor
SRV
= sludge removal valve
FV =
fi lter valve for Heat Pump circuit
V
= stop valves
EV
= expansion vessel
BPD =
backfl ow prevention device
F
= fl exible hose for Heat Pump connection
MAV
= manual air valve
HPSV
= Heat Pump safety valve set to 2.5 bar
HPIWS
= Heat Pump incoming water sensor
HPOWS
= Heat Pump outgoing water sensor
EBCP
= existing boiler circulator pump
EVE
= expansion vessel for existing installation
BSV
= existing boiler safety valve
OS
= Heat Pump HRC
70
Pilot outdoor temperature sensor
TC2
= heating circuit 2 room thermostat (optional)
FRM SP
= fl ow rate monitor for swimming pool circuit
S pool
= swimming pool sensor (optional extra included in
swimming pool kit)
C pool
= swimming pool circuit circulator pump
• Disconnect the HRC Pilot heating circulator pump, which is pre-connected at the factory
on terminals 5 and 6.
• Reconnect to terminals 2 and 3.
• Next connect C1CP for the swimming pool to terminals 5 and 6.