![auer HRC 70 PILOT-PREMIUM Installation And Operating Instructions Manual Download Page 6](http://html.mh-extra.com/html/auer/hrc-70-pilot-premium/hrc-70-pilot-premium_installation-and-operating-instructions-manual_3015803006.webp)
-
INSTALLER
7 & 11kW HRC
70
HIGH TEMPERATURE HEAT PUMP
-
6
2.1 - Standard c
onfi guration
2 - PRESENTATION
Indoor
installation
only
Outdoor
installation
only
The group is composed of an exterior unit (monobloc high
temperature Heat Pump, to be installed outdoors only) and an
interior unit (Pilot, to be installed indoors only) . These units are
linked together by a hydraulic connection and a communication
bus.
The air to water Heat Pump collects the calories from outdoor air
and transfers them to the heating water circuit with high energy
effi
ciency.
The Pilot maintains the regulation and hydraulic distribution of
the installation.
The Pilot is pre-equipped and designed for heating installations
in domestic or tertiary premises.
If the required heating capacity is higher than the capacity
delivered by the Heat Pump, the Pilot can provide an extra power
boost, either through the boiler or its electrical back-up (0-2-4- or
6kW, depending on how much is required).
N.B:
The Heat Pump is designed solely for heating purposes. It
cannot be used for cooling.
The Pilot is pre-confi gured for heating a radiator circuit which is
controlled from a room thermostat from the Heat Pump only.
You will need to confi gure the Pilot accordingly if you wish to
connect it to an existing boiler (or if using electrical back-up from
0 to 6kW) or when connecting it to an underfl oor heating circuit,
a secondary heating circuit, a domestic hot water system or a
swimming pool circuit.
2 230V single phase
power supply points
HRC Heat Pump
Outside (only)
Hydraulic
connection
Radiator
circuit
Room
thermostat
C
ommunica
tion bus
2-
cor
e shea
thed cable
Indoors (only)
HRC PILOT