INSTALLER
7 & 11kW HRC
70
HIGH TEMPERATURE HEAT PUMP
-
38
6.5.2 - Accessing calculated data
heat curv1
62
.
0
°
C
Target temperature at Heat
Pump inlet (where there is
only one circuit)
example
shedding
2
swim. pool
23
.
5
°
C
flow
0
Pt / opt
0
Load shedding status (
0
= load
shedding in progress,
1
= no
load shedding)
Swimming pool circuit water
temperature
Load shedding status for peak
and off -peak times (
0
= load
shedding in progress,
1
= no
load shedding)
example
example
example
data calc.
Accessing the Installer Menu:
• Press
• Turn the dial until the screen displays
"INST. MENU"
• Press
and
at the same time
•
Keep them held down simultaneously
for 3 sec.
Trr COMP 1
00:07
Time period between 2 start-
ups for the compressor
example
TSR COMP 1
00:03
h
TRS COMP 1
00:03
h
tmod COMP 1
00:04
h
Minimum stopping time for
compressor 1
Minimum running time for
compressor 1
Time delay before compressor
1 engages
example
example
example
• Press
at any time to return to the
data cALC
. screen.
N.B:
If 2 circuits are confi gured, the heating curve is displayed
for each circuit
heat curv1
62
.
0
°
C
Circuit 1 target temperature at
Heat Pump inlet (if 2 circuits)
example
heat curv2
57
.
0
°
C
Circuit 2 target temperature at
Heat Pump circuit (if 2 circuits)
example