INSTALLER
7 & 11kW HRC
70
HIGH TEMPERATURE HEAT PUMP
-
4
1.1 - Important information
1.2 - Safety instructions and advice
1 - PLEASE READ
IMMEDIATELY
These installation and operating instructions form part of the
appliances which they refer to.
In order for the warranty
to be valid, they must be read before using the
appliance.
This manual must be kept and passed on to
successive users for future reference. It will be
considered as evidence in case of litigation.
• The Heat Pump must only be installed outdoors.
• This appliance is not intended for use by people (including
children) who have reduced physical, sensory or mental
capacities, or by people who have insuffi
cient experience or
knowledge of the product, unless they are being supervised by
someone who is responsible for their safety and in possession of
the instructions on how the appliance should be used.
• Installing the Heat Pump indoors is
strictly forbidden
.
• The Heat Pump has an operating range of -20°C to 40°C. When
the temperature falls below -20°C, the installation is no longer
heated by the Heat Pump, but by the back-up.
• It is FORBIDDEN :
- to let the Heat Pump run using air intake which contains
solvents or explosive matter
- to use air intake which contains grease, dust or aerosol
particles
- to connect vented exhaust hoods
• It is
FORBIDDEN
to use the appliances if the installation is not
fi lled with water
• All work undertaken on the installation must be carried out by
a qualifi ed professional with the appliances disconnected from
the mains power supply.
• This appliance must be installed in accordance with national
electrical installation regulations.
• Check that the installation is equipped with a properly sized and
connected ground cable.
This CE-approved unit is in compliance with the essential
requirements of the following directives:
- low voltage 2006/95/CEE (standard EN 60.335.1)
- electromagnetic compatability 2004/108/CEE (standard EN
55014.1 / EN 55014.2).
• Any work undertaken on the refrigerant circuit must be carried
out by a qualifi ed professional with a category 1 certifi cate
of aptitude. It is prohibited to release refrigerant into the
atmosphere: it is mandatory to recover the refrigerant before
beginning any work on the circuit.
The high temperature Heat Pump absorbs the calories contained
in outdoor air, transforms them into useful energy and transfers
them to the heating water for your home. AUER cannot be held
responsible for any other usage of the appliance.
The safety advice and instructions which are given here must be
strictly respected.
Before making any connections, make sure that the appliances
are compatible with the installation.
Before switching the system on, make sure that the network
voltage to be applied to the appliances is the same as the voltage
indicated on their rating plates.
Before undertaking any maintenance or handling or in case of the
appliances functioning incorrectly or not at all, always disconnect
from the mains power supply and seek advice from a specialist.
AUER declines any responsibility for damage caused by these
instructions not being followed and any errors due to improper
handling, installation or usage.
These installation and operating instructions are subject to
change without prior notice.
- It is the responsibility of the installer and
the client to contact the electricity provider and
ensure that the appliance is compatible with
the power grid before connecting the HRC
70
Heat Pump (see the information form which is
an appendix to this document).
- The power grid impedance value must be less
than the Heat Pump impedance Z
max
(see §
"Connecting the HRC
70
Heat Pump to the power
supply").
- If electrical installation standards are not
respected, irreversible damage could be
sustained to the HRC
70
Heat Pump, which will
not be covered by the manufacturer’s warranty.
ELECTRICAL INSTALLATION
RECOMMENDATIONS
- Rinse and clean the hydraulic heating
circuit before connecting the Heat Pump
and Pilot.
- The appliance only works when fi lled with
water. Never switch the appliance on if it has not
been properly purged and fi lled with water.
- The fi lter valve protects the Heat Pump; an
annual check on the condition of the fi lter must
be carried out.
- We recommend that you check for sludge
and limescale from time to time and clean if
necessary. The appliance must be switched off
before any cleaning is undertaken.
- Always switch the appliance off before working
on any electrical parts.
Caution: the fan may still continue to run
through inertia even when the appliance has
been switched off .
- Never put water on the control components
or any electrical parts. Switch off the appliance
before cleaning.
HYDRAULIC INSTALLATION
RECOMMENDATIONS