6.6 - Sensor data curve charts
6.6.1 - Water inlet and outlet - de-icing sensor
- air intake sensor - sensors installed on
compressors 1 and 2 -
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1,0
90
100
110
120
130
140
°C
k
:
Temp.
(°C)
Value of
the sensor
(KOhms)
Temp.
(°C)
(KOhms)
Temp.
(°C)
(KOhms)
Temp.
(°C)
(KOhms)
-40
351.078
10
20.017
60
2.472
110
0.504
-35
251.277
15
15.768
65
2.068
115
0.439
-30
182.451
20
12.513
70
1.739
120
0.384
-25
133.827
25
10.000
75
1.469
125
0.336
-20
99.221
30
8.045
80
1.246
130
0.296
-15
74.316
35
6.514
85
1.061
135
0.261
-10
56.202
40
5.306
90
0.908
140
0.231
-5
42.894
45
4.348
95
0.779
145
0.204
0
33.024
50
3.583
100
0.672
5
25.607
55
2.968
105
0.581
Value of
Value of
Value of
the sensor
the sensor
the sensor
0
1
2
3
4
5
6
7
8
9
10
11
12
20
30
40
50
60
70
80
90
°C
k
:
6.7 - M
odifi cation
Any modifi cation of the device is
prohibited
. Any replacement of
components must be done by a professional with original parts
from the manufacturer.
6.8 - Decommissioning
In the event of a prolonged absence with a power cut to the
housing and product, ask a qualifi ed professional to drain the
product or protect it from freezing.
6.8.1- Interim Decommissioning of Product
6.8.2- Final decommissioning of the product
Turn off the product to a specialized installer.
6.9 - Recycling and Disposal
Entrust the disposal of the packaging to the installer who installed
the product.
The above symbol requires:
- Do not dispose of the product with the household waste.
- Dispose of the product at a collection point for used electrical
and electronic equipment.
The product contains refrigerant R290 (propane).
- Routinely dispose of refrigerant to qualifi ed personnel.
-Follow the general safety conditions.
6.9.1- Disposal of refrigerant