5.2 - Installation site
The Heat pump is designed to be installed outdoors exclusively, while respecting a minimum of free space around the appliance in an area
free from excessive levels of dust. It should never be placed in an enclosed space.
The Heat pump is designed to operate in rainy weather conditions, although it can be installed under a well ventilated shelter (with a large
enough opening to allow suffi
cient air fl ow for intake and exhaust).
Placed on the
ground or on a
terrace
(empty area)
Placed against a wall
+3dB (A)
Placed in a yard
+9dB (A)
Placed in a corner
+6dB (A)
5.2.2 - Minimum distances for placement
Minimum distances to be respected for the placement of the Heat
pump:
≥ 30cm
≥ 1m
≥ 1m
≥ 30cm
≥ 30cm
≥ 2m
5.2.1 - Accepted installation sites
Neighbouring
home
The noise prevention screen must be made of insulated
materials.
Neighbouring
home
Neighbouring
home
Off set from all
windows
5.2.3 - Prohibited installation sites
Underneath a
window
Neighbouring
home