CHAPTER 7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm
dsx1LineStatusChange
1 dsx1NoAlarm No alarm present
2 dsx1RcvFarEndLOF Far end LOF (a.k.a., Yellow Alarm)
4 dsx1XmtFarEndLOF Near end sending LOF Indication
8 dsx1RcvAIS Far end sending AIS
16 dsx1XmtAIS Near end sending AIS
32 dsx1LossOfFrame Near end LOF (a.k.a., Red Alarm)
64 dsx1LossOfSignal Near end Loss Of Signal
128 dsx1LoopbackState Near end is looped
256 dsx1T16AIS E1 TS16 AIS
512 dsx1RcvFarEndLOMF Far End Sending TS16 LOMF
1024 dsx1XmtFarEndLOMF Near End Sending TS16
LOMF
2048 dsx1RcvTestCode Near End detects a test code
4096 dsx1OtherFailure Any line status not defined
here
8192 dsx1UnavailSigState Near End in Unavailable Signal
State
16384 dsx1NetEquipOOS Carrier Equipment Out of
Service
32768 dsx1RcvPayloadAIS DS2 Payload AIS
65536 dsx1Ds2PerfThreshold DS2 Performance
Threshold Exceeded
B-Channel Alarm
The alarm is applicable only to digital PSTN interfaces.
Table 7-8: acBChannelAlarm
Alarm
acBChannelAlarm
OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.85
Default
Severity
Minor
Source
Varbind
Text
Interfaces#0/Trunk#<m>, where m is the trunk interface number, 1 being the
first trunk
Event
communicationsAlarm
- 102 -