key to confirm. The display will show “JUMP” for a 

second and then the 

controller will start executing the specified program step.  
 

11.

 

Connect the Sensor to the Controller 

The connector of sensor contains a slot for fitting pin connection. It also has a 
spring lock to prevent disconnections from accidental pulling on the cable.  
 
To install the sensor to the controller: 1) Identify the key on the male sensor 
connector (Figure 5, a) and the notch on the female connector (Figure 5, b). 2) 
Hold the tail of the female connector, align the notch and the key, and push the 
female connector forward.   
 
To remove the connector, hold the spring loaded collar on the female 
connector and pull it back. Please see Figure 6. 
 

(a) 

 

(b) 

 

(c) 

Figure 5. Install the sensor. 

 

 

Figure 6. Remove the sensor. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Auber Instruments 

5755 North Point Parkway, Suite 99 

Alpharetta, GA 30022, USA 

www.auberins.com

 

E-mail: [email protected] Tel: 770-569-8420

 

Summary of Contents for TD400P

Page 1: ...Minute Max Programmable Time 799 2 hours or 33 3 days for total 8 steps Audio Alarm High and low limit Sensor Type Silicon Band Gap Sensor Sensor Size 0 25 OD 6 35 mm x 1 25mm long Ambient Temperature 20 50 C 0 120 F Dimension 91 x 140 x 46mm Input Power 85 242 VAC 50 Hz 60 Hz Sensor Cable Length 6 ft 2 m Power Cable Length 3 ft 1 m Warranty One 1 year Either heating or cooling device is limited t...

Page 2: ...erential 0 5 99 9 5 0 4 oFS Ofs Temp Offset 99 9 99 9 0 5 AS AS Anti short Cycle Delay only for cooling socket M 0 M99 0 99 min M 0 6 A M A M Power Outage Startup Modes S M C S 7 PrG PrG Program Modes on off ON 8 SFA SFA Sensor Failure Operation 0 0 0 1 1 0 0 0 9 Time time Time unit H M H 10 C F C F Temperature unit ºF ºC ºF 11 Note 1 AH deviation high alarm AL deviation low alarm Assuming measure...

Page 3: ...ess temperature alternatively This mode is suitable for situations where the operator s attention is needed after power interruption occurs Note 8 PrG Program Mode When PrG is set to ON user can program up to 8 steps Section 7 When set it to OFF this multi step function is disabled and controller is in single step mode User can only set C 1 value without timer t 1 when disabled Please be aware tha...

Page 4: ... part of the program by jumping to a specified program step For example the controller has run 3 minutes in its 2nd step If the user want to skip the rest of the 2nd step and the entire 4th step then the user can jump to step 4 To jump to a specified step 1 Put the controller in either Program Hold or Stop Mode 2 Press STEP key so the controller will flash J PX where J indicates this operation is ...

Page 5: ...ble To install the sensor to the controller 1 Identify the key on the male sensor connector Figure 5 a and the notch on the female connector Figure 5 b 2 Hold the tail of the female connector align the notch and the key and push the female connector forward To remove the connector hold the spring loaded collar on the female connector and pull it back Please see Figure 6 a b c Figure 5 Install the ...

Reviews: