13
IMPORTANT – If this alarm does not test properly return it immediately for
repair or replacement.
The visual indicators have two distinct functions: On and Flashing.
The “On” function is indicated by constant solid brightness of the LED. The
“Flashing” function is indicated by the LED blinking once every second.
The audible indicator has two distinct functions: Alarm and Fault.
In the “Alarm” function, the alarm will sound four “beeps” in 1 second followed by 5
seconds of silence. After 4 minutes of alarming, each silence will last for 1 minute.
In the “fault” function, the alarm will last for 1 minute. In the “Fault” function, the
alarm will sound a “chirp” once every 40 seconds until the fault is cleared.
INSTALLATION INSTRUCTIONS
•
LP/CO units when possible should be mounted lower to detect LP gas first due
to its explosive nature and CO will be detected through air current circulation.
•
Select a location as close as possible to appliances that could be potential
sources of LP gas leaks and where the initial concentration may be greatest.
•
DO NOT INSTALL
next to doors or windows that may dilute the concentration
of any LP gas presents in the environment and preclude a timely alarm signal.
•
DO NOT INSTALL
the detector in a closet or in a location that could be come
obstructed by a curtain, hanging clothes or any other objects.
•
DO NOT LOCATE
detector where it could be exposed to splashes of water or
grease or where it could be damaged by impact with moving objects (i.e.
furniture, feet, etc.).
CAUTION
Installation should be performed by a qualified technician