10
POWER CONSERVATION MODE
Current Draw
10 mA
Temperature
-40° to 70° C (-40° to 158°F)
Storage Temperature
-40° to 70° C (-40° to 158°F)
Humidity
15 to 90%
Warranty
Limited, 2 year
Alarm Lifetime
7 years ( powered operation)
Standards
ETL tested to UL 2034 & UL 1484 Residential and RV and
Complies with CSA 6.19
For Service and Information Contact
Atwood Mobile Products LLC, 1874 South Pioneer Road Salt Lake City, Utah 84104-4226
Consumer Service Department, 1120 North Main, Elkhart, IN 46514 USA.
Phone: 866-869-3118
ALARM OPERATION
The alarm includes four LED indicators
, an LP, CO and LPCO oscillating multi-tone
audible alarms
, and one Test/Reset button that provide interaction and feed back
with your alarm. The indicators allow you to troubleshoot your alarm and to
determine the proper actions to take. The visual indicators are labeled Power, Fault,
Carbon Monoxide, and Propane.
The alarm operates in six separate modes that will be identified in this section.
Power Off Mode
This mode indicates that there is insufficient power provided to the alarm. The
indicators and button will not function in this mode. Sufficient power must be
provided to the alarm to exit this mode.
Normal Gas Detection Mode
This mode indicates that gas concentrations are continuously monitored. It also
indicates that gas concentrations are at safe levels. In this mode the Power
indicator will be lit, and all other indicators will not be active. The Test function for
the Test/Reset button will be active.