background image

After reading this manual, be sure to keep it in a place where the users can refer to it whenever necessary.

WARNING

 

1-16.Our products use nickel-hydrogen rechargeable batteries. It is a recycled resource. 

1-18.If a situation other than the contents of this manual occurs, stop using this meter immediately and contact us.

    

substances.

   

 If you need to replace the battery,  please leave it to us.

1-17.Turn off the power of all devices before connecting to an external device.

   

Failure to do so may result in electric shock or equipment damage.

    

malfunction.

   ・

Do not use a DC power supply or engine generator. It may cause a malfunction or fire.

   ・

Recharge the battery in a well-ventilated place. Do not cover it with any sheet like a cloth while charging.

1-14.Be careful of electric shock. Do not touch the power plug with wet hands. It may result in electric shock. 
1-15.Do not throw the battery (built into the main body) into a fire. The battery will explode or release harmful

    

This meter is a precision equipment, do not disassemble it.

    

If equipment malfunctions occur due to excessive impact or vibration, it will not only fail to perform adequately,

    

but also cause accidents and injuries.

1-13.Charge it properly.

   ・

Use only the supplied AC adaptor for charging. Using an AC adaptor other than the one supplied may cause a

1-11.Ask your dealer for repairs

.

   ・

Do not modify this meter.

   ・

Be sure to contact the dealer where you purchased this meter for repairs. If it is repaired by a person without

    

repair knowledge or skills, it will not only fail to perform adequately, but also cause accidents and injuries.

1-12.Do not disassemble this meter, or subject it to strong impact or vibration.

    

function.

  ・

Check if there are any abnormalities in all parts that affect the use.

  ・ 

Replace the parts according to this manual.

1-10.Use the specified accessories, appropriate bits and sockets. Do not use any accessories or attachments not 

   

described in this manual.

  

In the following cases, switch off the main body and disconnect the plug from the power supply.

  ・

When not used or charged.

  ・

When other danger is predictable.

1-9.Check if there are any damaged parts.

  ・

Before use, check

 

it

 

thoroughly for

 

any damage, and ensure that it works normally and performs the designated

  

 cords out from the outlet or connector.

1-8.For safe and efficient operation

  ・

Check the main body and attachments, etc. regularly, and use the ones that are not deformed and worn.

  ・

 

Follow the operation manual when replacing accessories.

  ・

Check the cords and extension cords regularly, and replace them if they are damaged.

 

Use in a place where the temperature is constant (about 23 

) , if possible.

 

Make sure the workplace is adequately lit.

 

Do not use or charge in a place with flammable liquid or gas.

1-6.Keep children away. Only the operator is permitted to enter the workplace.
1-7.Don not handle the cords roughly. Do not hold the cords to carry the main body with the cords attached, or pull the 

1-2.Do not use this meter to measure an impact type fastening tool.
1-3.Make sure the main body is firmly secured so that it will not swing around when measuring.
1-4.Always keep the workplace clean. A cluttered place or workbench could cause an accident.
1-5.Also consider the surrounding conditions of the workplace.

 

Do not use in a place with high temperatures, high humidity, direct sunlight, or a lot of dust or dirt.

1.Safety precautions 

To prevent accidents such as fire, electric shock and injury, be sure to observe the following "Safety Precautions".

Read all of the "Safety Precautions" carefully before using this meter, and follow the instructions to use it correctly.

1-1.Do not apply a torque that exceeds the allowable load. If a torque exceeding the allowable range is applied, 
      the detector may be damaged, resulting in an accident or injury.

Summary of Contents for AD-TM Series

Page 1: ...Digital Torque Meter Operation Manual AD TM Series ATTONIC CO LTD...

Page 2: ...s manual 1 10 Use the specified accessories appropriate bits and sockets Do not use any accessories or attachments not described in this manual In the following cases switch off the main body and disc...

Page 3: ...not apply large twisting forces lateral bending forces and forces that exceed a tolerance to the detection shaft otherwise the detector will be damaged 2 6 Do not use this meter for any purpose other...

Page 4: ...n shaft Drive width 17 socket Display DC IN Power Jack FUN Switch Rubber Foot RES Switch Mounting hole Mounting screws for the main body M5 2places 3 Parts names 3 1 The name and application area of p...

Page 5: ...are attached AD TM10 TC 3 M4 Screw 2 TSS 10 M4 Screw 2 With Spring Spare screw 2 screws each are attached AD TM50 TC 6 M5 Screw 2 TSS 30 M6 Screw 3 With Spring Spare screw 2 screws each are attached A...

Page 6: ...AD 20 USB cable AD USB 1 5 Data output ASCII format Baud rate 19200 Dedicated charger IN AC100V 240V OUT DC9V Dimension About172 L 210 W 55 75 with the measuring socket included H Usage time About 12...

Page 7: ...this meter firmly with a tool etc 5 3 Attachment installation Use the supplied attachments according to the measurement conditions If you cannot measure with the supplied attachments please contact us...

Page 8: ...anged The display becomes 0 zero when RES switch is pressed Exit when the screen goes off Set other functions Right rotation test Left rotation test Long press the POW switch when the test is finished...

Page 9: ...CANCEL and press the POW switch to complete the setting 7 1 Set measurement mode Initial Setting TRACK You can switch the measurement mode Switch between TRACK mode and PEAK mode by pressing the DAT s...

Page 10: ...tion will be changed and when the force exceeds 1 00N m a short intermittent sound will be heard The setting value should be entered as the value of side instead of an absolute value A short intermitt...

Page 11: ...g excessive force accidentally The setting can be set by 10 up to 120 The setting value should be entered as the value of side instead of a absolute value A short intermittent sound will be heard if t...

Page 12: ...again When reset the data will be saved automatically Work efficiency will increase when used in combination with printer output You can switch ON OFF repeatedly by pressing the DAT switch It is a se...

Page 13: ...ion is set to and left rotation is set to Comparator Intermittent sound fast Remove the load and press RES switch Comparator Intermittent sound slow Remove the load and press RES switch Switch operati...

Page 14: ...e printer Returns to the first setting 7 1 Measurement mode 7 9 7 10 7 11 7 12 7 13 7 14 7 15 Page to refer 7 1 7 2 7 3 7 4 7 5 7 6 7 7 7 8 7 15 Set printer output PO Initial Setting OFF Set whether t...

Page 15: ...yed in the upper right corner of the screen If MO is not displayed long press the DAT switch again until you hear a beep Please note that it is set longer so that the measurement mode will not be swit...

Page 16: ...er of the screen will be N 020 The value of in N cannot be changed Short press the FUN switch to move to all clear function Short press the FUN switch to move to history data display function The disp...

Page 17: ...AV display in the upper right corner of the screen disappears and the meter becomes measurement mode 9 1 MAX MIN AVE values 9 Checking method on MAX MIN AVE values and function description You can ch...

Page 18: ...hen the display value of side is greater than or equal to the setting value in PP mode ON when it is overloaded Digimatic CLK Digimatic DAT Digimatic RDY RES switch ON when the value is greater than o...

Page 19: ...ion to external devices Do not short circuit It may cause a malfunction Do not apply voltage from outside 12 Digimatic communication connection Printer DP 1VA The cable is available as an option The m...

Page 20: ...PPED ON POWER_OFF Auto power off ON permission OFF none POWER_OFF ON AUTO_CLEAR ALL CLEAR ON permission OFF none AUTO_CLEAR ON MIN_DIGIT Minimum digit display ON permission OFF none MIN_DIGIT OFF BUZZ...