7.1 CLI provides ASCII-based interface
The command line interface (CLI) provides access to the ATTO iPBridge
Services through a set of ASCII
commands. CLI commands may be entered while in CLI mode.
iPBridge Services provide configuration and
monitoring for the iPBridge. CLI commands may
be entered while in a Telnet session or on the
ExpressNAV interface
Advanced CLI
page
using the Ethernet port or while in a Telnet or
standard emulation program using the serial port.
• CLI commands are context sensitive and
generally follow a standard format
[Get | Set] Command [Parameter 1 |
Parameter 2]
followed by the
return
or
enter
key
• CLI commands are case insensitive: you may
type all upper or all lower case or a mixture.
Upper and lower case in this manual and the
help
screen are for clarification only.
• Commands generally have three types of
operation:
get, set
and
immediate
.
• The
get
form returns the value of a parameter or
setting and is an informational command.
Responses
to
get
commands are specified in
the Results field for each command, followed by
Ready
.
• The
set
form is an action that changes the value
of a parameter or configuration setting. It may
require a
SaveConfiguration
command and a
restart of the system before it is implemented.
The restart can be accomplished as part of the
SaveConfiguration
command or by using a
separate
FirmwareRestar
t command. A
number of set commands may be issued before
the
SaveConfiguration
command.
Responses
to
set
commands are either an error
message or
Ready. *
. The asterisk indicates
you must use a
SaveConfiguration
command
to finalize the
set
command.
SaveConfiguration
asks if you want to restart
the system or not.
•
Set
commands which do not require a
SaveConfiguration
command, defined as
Immediate
commands, are immediately
executed.
Responses
to
Immediate
commands are either
an error message or data results followed by
Ready.
Exhibit 7.1-1 Symbols, typefaces and abbreviations used to indicate functions and elements of the
command line interface used in this manual.
Command conventions
Symbol Indicates
Symbol
Indicates
[ ]
Required entry
Boldface words must be typed as they appear
< >
Optional entry
Italicized words Arguments which must be replaced by whatever they
represent
|
pick one of
Dp
Data port
…
Ellipses, repetition of preceding item
sb
SCSI bus number
\n
end of line
sl
SCSI LUN ID (0 <= sl <= 7)
-
a range (6 – 9 = 6, 7, 8, 9)
st
SCSI target ID (0 <= st <= 15)
Summary of Contents for iPBridge 1550
Page 2: ......
Page 3: ......
Page 25: ...16 Installation mapping Exhibit 2 1 2 Target management choices in ATTO ExpressNAV v...
Page 27: ...18 Installation mapping...
Page 57: ...48 CLI commands...