30
4.5
FUNCTION AND DISPLAYING THE TEXT BY IGNITING OR
REFILLING THE FUEL
After pressing the „+“button it comes to the following procedure:
The boiler is started the indicator light 1 flashes and the ignition is running
The text is displayed:
DO NOT OPEN!
WAIT
the flue gas fan and regulation of burning are started
the supply pump and regulation of the return and supply valve are started
the generator of an alternative energy is stopped by the switch
after 5 seconds appears the text:
FUEL DOOR UNLOCKED
and in 10 seconds is the electromagnetic door-lock released (is it is disposable)
after 10 seconds appears the text:
CAUTION!
OPEN SLOWLY!
after 5 seconds appears the text:
IGNITION
Prepare and ignite the fuel following the instructions on the page 11, close the feeding door
partly. If the bar chart is full, the fuel is ignited, close the door.
If the bar chart is full and ignition or process of fuel loading takes more than 15 minutes, it is
switched to the operating display mode.
The regulator stops the boiler after 15 minutes, if:
There was no ignition and the regulator started the burning process despite of that fact,
because it was accidentally started by the „+“button.
The fire extinguished after closing the door, because there was lack of wood splinters or the
fuel is too wet.
4.6
DISPLAY OF THE OPERATING MODE BY THE BOILER STARTED
Text on display:
BOILER TEMPERATURE
˚C
After 5 seconds appears the next text:
FLUE GAS TEMPERATURE
˚C
This text appears on display every 5 seconds.