![ATTACK AWP 25 Instructions For Use Manual Download Page 90](http://html1.mh-extra.com/html/attack/awp-25/awp-25_instructions-for-use-manual_3005323090.webp)
89
Service parameters, page 5
Pic. 98
Number of suction retries –
the number of suction repeats in failed attempts
Turbine max runtime -
determines how long a vacuum fan will suck in pellets without a break
Turbine rest time-
determines how long the turbine will have a pause in suction after which it
will be switched on again
Power regulator worktime –
control time PID control model (set from factory)
Power regulator P – Part
– proportional part of PID control model (set from factory)
Power regulator D – Part -
differential part of PID control model (set from factory)
Power regulator I – Part
– integral part of PID control model (set factory setting)
Buffer uninstalled -
after activation of this function the boiler will be controlled according to
the temperature of the accumulation tank