ATTACK AWP 25 Instructions For Use Manual Download Page 32

 

31 

We start the boiler by pushing the button START. There will be displayed Main Screen  where we 
can choose among three types WOOD, PELLET, COMBI (pic. 17 and 18): 

 

 

 

Starting the boiler 

Pic. 17

 

 

 

Start Options 

Pic. 18

Start Options: 
WOOD – 

we choose it when we want to heat only with  wood

 

 

PELLETS - 

we choose it when we want to heat only with pellets  

COMBI – 

we choose in case we want the boiler to be switched into the PELLETS mode after 

burning the wood out and if there will be demand for further heating

 

 

Summary of Contents for AWP 25

Page 1: ...www attack sk ATTACK WOOD PELLET Instruction for use EN EN 06 2019...

Page 2: ......

Page 3: ...THE BOILER 13 2 4 3 CONNECTION TO THE ELECTRICITY MAINS 13 2 4 4 CONNECTION OF THE EXTERNAL PELLET TANK 14 2 4 5 LEFT DOOR VERSION 14 2 4 6 CHOICE AND WAY OF CONNECTION OF THE CONTROL AND SAFETY ELEM...

Page 4: ...17 BOILER CLEANING 74 18 ASSEMBLY AND DISSASSEMBLY OF THE REFRACTORY ITEMS 75 19 TABLE OF RELATION OF THE RESISTANCE AND THE TEMPERATURE OF THE SENSOR PT 1000 76 20 ELECTRICAL CONNECTION SCHEME 77 21...

Page 5: ...t and we reserve right to make technical changes of products without previous announcement SAFETY 1 2 The following three warning signs are used in this manual for illustration of the threat of danger...

Page 6: ...riendly boiler that saves environment by efficient burning of biomass The user gets the advantage of low operating costs from wood combustion as well as the convenience of the heating system comparabl...

Page 7: ...s possible to burn soft and hard chopped fuel wood with the heat value 15 17 MJ kg Particularly suitable is beech oak fir spruce pine poplar alder willow birch ash wych hazel locust always within the...

Page 8: ...ERNATIVE FUELS 1 7 3 It is possible to use the wood briquettes made from pressed wood sawdust without any addi tional adhesives or bidning materials The briquettes must be always mixed in the appropri...

Page 9: ...move the upper boiler cover before hanging the boiler on the hanging eye Handling the boiler with the hanging screw with eye Pic 2 GENERAL CONDITIONS OF INSTALLATION 2 2 The boiler can only be install...

Page 10: ...places by using the approximative corrections in environment ISO 11202 2010 STN EN ISO 12100 Safety of machines General principles of construction of ma chines Consideration and elimination of the ris...

Page 11: ...he grade of flammability not approved under the STN 73 0853 400 mm Examples of classification of the building materials by their degree of flammability degree of flammability A inflammable bricks bloc...

Page 12: ...lues under the STN 07 7401 1992 The water must be pure colourless without suspendous sub stances oils nor chemically aggressive ingredients The water cannot be acidic pH must be higher than 7 2 Callos...

Page 13: ...heating water flowing into the boiler over 65 C by setting the thermostatic head to the level 5 6 When the individual thermal regulation mixing valve is used it is possible to control the temperature...

Page 14: ...not possible to connect the boiler to the chimney hole directly then the appropriate extension should be as short as possible of up to 1 m length without any additional heating area and it should asc...

Page 15: ...2 4 6 There is an option of the ATTACK WOOD PELLET boiler with the left door door hinges on the left side It can be done before the boiler start up or later when the boiler is not in service The main...

Page 16: ...DANGER The heating system must be equipped with a safety valve against exceeding the pressure in the boiler 2 5 bar This valve should be placed on the flow connection of the boiler always installed i...

Page 17: ...the temperature of 10 15 C and operating overpressure of 2 6 bar ensuring the safe operation even by a power failure The thermostatic valve at the outlet of the aftercooling circuit with the sensor pl...

Page 18: ...accumulation tank from 20 C to 62 C despite of the fact that the 10 kW are being taken This is a safe and economical operation when the heat is not taken into the waste the boiler was cooled down by...

Page 19: ...eating water AS standard accumulation tank intended for the accumulation of energy of the heating water equipped with a coil for connection of the solar panels HR combined accumulation tank for accumu...

Page 20: ...is not valid and the customer has to carry the costs by damage The warranty is valid only in the case that the boiler was installed and operated in the fol lowing way together with device for the boi...

Page 21: ...protection IP 21 El input by a nominal output W 90 El input by a minimal output W 32 El input in the standby mode W 15 Efficiency of the wood boiler 90 5 Efficiency of the pellet boiler 90 4 Boiler c...

Page 22: ...TTACK WOOD PELLET 25 4 1 Description of particular boiler parts Pic 6 426 312 G 6 4 G 1 2 G1 2 1 2 5 9 1 0 0 50 50 1 6 4 1 6 0 4 1 6 4 G 6 4 1 5 0 8 611 776 1125 150 1 6 0 4 568 904 951 3 0 0 1207 13...

Page 23: ...serious damage to health or proper ty It is forbidden to open any door behind the main door during the operation EMERGENCY ACTIONS 5 2 Boiler overheating If the boiler is in WOOD mode and it starts to...

Page 24: ...f the aftercooling circuit by pressing the valve manually The boiler must be operated in conformity with the instructions given in this manual to achieve the quality function CAUTION There may come be...

Page 25: ...n process in the boiler ATTACK WOOD PELLET is controlled by the modern elec tronics equipped with software operating on the basis of the latest knowledge in the field of the biomass burning There is a...

Page 26: ...he tank s volume The regulation of the WOOD burning is ensured by the Lambda probe together with the con trolled rotations of the exhaust fan controlled inlet of the primary and the secondary air meas...

Page 27: ...test functionality of some connected electrical devices Click the button of General settings and then the button TEST for the entry into the Testmode of the boiler pic 9 pic 10 Click on button Genera...

Page 28: ...he button next to the device or by writing value in pic 11 12 13 Testing activation of devices unable to be changed modulated and devices able to be Pic 11 changed modulated Testing activation of devi...

Page 29: ...f any devices it is always needed to turn off these de vices After finishing of the testing come out from test mode with the button of service key We get into the Main Screen where we again click on s...

Page 30: ...29 Coming out from Test menu 2 Pic 15 Coming out from Test menu 3 Pic 16...

Page 31: ...the WOOD mode at any time it is needed to wait for burning the wood out After burn ing the wood out it is possible to get into another mode The PELLET mode is aimed for pellet combustion basically mak...

Page 32: ...ic 17 and 18 Starting the boiler Pic 17 Start Options Pic 18 Start Options WOOD we choose it when we want to heat only with wood PELLETS we choose it when we want to heat only with pellets COMBI we ch...

Page 33: ...ring the day before or if there are cinders remained in the feeding chamber The automatic mode of lighting up the wood can be used after the boiler is cleaned and there are no cinders to make it easie...

Page 34: ...main in the ash contain the usable energy and they enable faster lighting up the wood The feeding chamber is cleaned through the middle door by the fire hook See the chapter 17 Cleaning 3 Open the doo...

Page 35: ...hem Preparation for lighting up the wood Pic 21 5 Put the wood of a smaller diameter chips of 20 20 mm on the cardboard pic 12 to make the process of lighting up faster and more stable Put the casual...

Page 36: ...5 The way to prepare the wood for lighting up Pic 22 Loading the full chamber Pic 23 6 Close the upper and the bottom door manually light up through the middle door only 7 Click on button START pic 24...

Page 37: ...36 Starting the boiler Pic 24 8 There will be displayed Start Options where you choose the option WOOD pic 25 Choosing WOOD mode Pic 25...

Page 38: ...ition 5 output coils works on by automatic ignition 10 Light the pellets on the bottom through the middle door by a lighter Keep themiddle door partly open until the cardboard and the wood chips light...

Page 39: ...n Pic 27 All operational information are displayed in information menu You get into information menu by clicking on button i Entry into information menu Pic 28 Immediately after firing up the boiler i...

Page 40: ...e phase coming when the flue gas temperature rises dur ing the set time in parameters If the flue gas temperature rises during another time set in parameters the boiler crosses into Control phase Pre...

Page 41: ...comes Glow Ember Protec tion phase pic 32 Glow Ember Protection phase Pic 32 CAUTION If the flue gas temperaturewill not rise in 30 minutes there is written the lack of fuel In case you decide to turn...

Page 42: ...election Pic 33 There will be displayed message that the burning has already started if you really want to stop Then confirm that you really want to turn the boiler off pic 34 Turning the WOOD mode of...

Page 43: ...The problems with the automatic wood ignition may occur due to the cold chimney or in summer when there is a chimney draught naturally decreased Thereby it is necessary to consider the automatic wood...

Page 44: ...43 Loading the wood into the chamber by the automatic light up Pic 36 Loading the full chamber Pic 37 3 Close all door upper middle bottom main ones 4 Click on button START pic 38...

Page 45: ...he option WOOD pic 39 Choosing WOOD mode Pic 39 6 After choosing WOOD mode there are displayed Start Options where we choose automatic ignition pic 40 Before the automatic ignition choose its paramete...

Page 46: ...the wood by the pellet section should be well considered By too high power there can occur excessive release of gaseous substances from the wood and the smoke from the loading chamber into the primary...

Page 47: ...ignition of wood Pic 41 Immediately after starting of the boiler it is in the Pre Flushing phase pic 42 Pre Flushing of the burner Pic 42 After Pre Flushing of the burner there comes the phase of Fil...

Page 48: ...ner there comes the phase of Ignition pic 44 Phase of Pellet Ignition Pic 44 CAUTION In case of unsuccessful ignition there comes Ignition no 2 It is possible to set the number of repeated ignitions i...

Page 49: ...5 After Pre Heating of pellets there comes the phase of Regulation of pellets pic 46 Regulation of pellets phase Pic 46 After the phase of Regulation of pellets the burner shuts down and there comes P...

Page 50: ...egulation mode Pic 48 CAUTION If the flue gas temperature does not rise above 90 C during 5 minutes during the regulation the boiler will report a fuel shortage pic 49 If the flue gas temperature does...

Page 51: ...50 Message Missing Fuel Pic 49 Burn Out mode Pic 50...

Page 52: ...nly with pellets CAUTION For functionality of operation with PELLETS it is needed to have activated timer for the days you want to heat with pellets The timer is activated from production More informa...

Page 53: ...ion menu there you can see all operational information pic 53 Displaying operational information Pic 53 2 Then the mode of Pre flushing of the burner comes pic 54 where the electronics checks if the p...

Page 54: ...53 Mode of Pre flushing Pic 54 3 After Pre flushing there is the mode of pellet filling into the burner pic 55 and pellet s igni tion pic 56 Mode of Filling of pellets into the burner Pic 55...

Page 55: ...Ignition no 2 It is possible to set the number of repeated ignition in advanced boiler s parameters 4 After pellet ignition there comes Pre Heating phase pic 57 Pre Heating Phase Pic 57 5 After Pre He...

Page 56: ...eded 2 When the accumulation tank temperature is reached if there are installed sensors in accumu lation tank 3 By boiler s timer 4 By room thermostat 5 When there is mode failure 6 After the maximum...

Page 57: ...ture is reached 1 Pic 60 Boiler shutdown from the reason the accumulation tank temperature is reached 2 Pic 61 6 After burning the burner will be cleaned and shut down the boiler remains in standby mo...

Page 58: ...ed from production More information you can find in article no 12 TIMER SETTINGS DANGER The combined mode serves for operation with either of the fuel types the WOOD or the PELLETS Never try to burn W...

Page 59: ...pellets at the same time After choosing COMBI mode it is needed to choose the ignition between manual and automatic pic 64 Selection of wood ignition in COMBI mode Pic 64 If the boiler was started wi...

Page 60: ...he boiler during the operation with pellets The pellet operation is stopped in 15 seconds if the feeding door is opened 8 DISPLAYING INFORMATION During and also out of the boiler operation it is possi...

Page 61: ...c information about the boiler state boiler temperature flue gas temperature actual value of the oxygen in the flue gas presence of the flame in the combustion chamber the photocell cycle of the pelle...

Page 62: ...f the burner ventilator position of the primary and sec ondary flap serving to control the wood gasification process Pic 23 Window 3 Information Pic 68 The third page the Information 3 displays the st...

Page 63: ...K WOOD PELLET enables to set general settings for correct boiler s operation like boiler s temperature flue gas temperature temperature of heat pump s starting etc pic 69 Entry to parameter s settings...

Page 64: ...ty approximate time after which the external pellet tank gets empty Set night from hour if the heating circuit is connected we determine the hour of night start when the heating circuit can reduce the...

Page 65: ...64 Displaying setting of sensors s in accumulation tank temperature Pic 72 There will be displayed table with the settings of accumulation tank s control pic 73 Setting of accumulation tank Pic 73...

Page 66: ...boiler is switched for PELLET mode Middle sensor Limit OFF the temperature above which the temperature of the middle sensor rises in the accumulation tank the boiler switches off 10 SPECIAL SETTINGS...

Page 67: ...or the electrical supply of the boiler falls out for some reason it can keep the time and date for about 3 days Screensaver time when the screen saver will be activated Program version displays inform...

Page 68: ...le via the local network and via internet as well It is necessary to have the IP address from the internet provider to have an access from internet For displaying General Internet connection settings...

Page 69: ...lly if you have a static IP address IP address settings Pic 78 The boiler can also be controlled and accessed via a smartphone namely Android Desktop 169 iOS Mocha VNC Lite Destination port 5900 Passw...

Page 70: ...operation for pellets For displaying boiler s timer click on service key and then on symbol of timer pic 80 If the timer is not activated in PELLET mode the boiler will not start up The timer is acti...

Page 71: ...te new software is available in ZIP file there is another folder copy all files from the folder to a blank USB max 2 GB USB must be formatted to FAT32 switch off the boiler with the switch insert the...

Page 72: ...71 New Software Update Pic 82...

Page 73: ...not possible to re move the malfunction or to select the desired boiler mode the boiler must be restarted We enter into General settings and click on floppy disk of the boiler pic 84 The boiler will r...

Page 74: ...on during its life it is necessary to do the maintenance The frequency of the maintenance depends on the frequency of operation and usage of the boiler The maintenance of the heating system and the bo...

Page 75: ...the bottom space form dirts The frequency of clean ing depends on the quality humidity of wood and the intensity of heating chimney draught and other conditions We recommend to clean the boiler 1 a we...

Page 76: ...door on the water rib and shift it totally rearwards Then insert the item number 2 through the bottom door as well put it on the water rib and shift it snugly to the item number 1 Prepare the sealing...

Page 77: ...90 1 721 200 1 758 210 1 795 220 1 831 230 1 868 240 1 904 250 1 940 By measuring the resistance of the sensor and the temperature using the energy meter you can easily check if the sensor is broken a...

Page 78: ...ification part M1 motor of the vacuum pellet supply M2 motor of the gear for turbulator cleaning M3 exhaust fan EL electrical lock MD end switch of the main door FD end switch of the door of the feedi...

Page 79: ...NC R 1 2 3 4 5 6 7 8 9 L L N N 24 PE PE N L N L 24 L N X35 X34 X33 X32 X31 1 2 3 4 22V PE 1 2 22V PE 3 4 F M M F M F F C D P S 1 2 PE L N F 3 4 A E D A E D A E D A E D A B A B A B C A B D C M4 FL CL L...

Page 80: ...L N PE L_O L_C N PE X30 X29 X28 X27 X26X25 X24X23 X22 X17X16 X15X14 X21X20X19X18 X36 X37 M1 M2 M3 A B D C M G F E H LAN CARD LAN Tex Tb LS CO E PS A F MD FD EL 3 4 M 3 3 A B 1 1 2 L N F M 1 2 STB 3 2...

Page 81: ...the temperature sensors in the accumulation tank are correctly installed For activation of starting function of the boiler click on symbol of heating circuit pic 87 Click for displaying Heating circui...

Page 82: ...iption of Heating circuit Pic 88 To enable the automatic boiler start function click the boiler symbol Pic 49 where you can see the parameter table Pic 90 Click for activation of automatic boiler s fu...

Page 83: ...ostat this function must always be activated if you want the boiler to be con trolled according to the storage tank temperatures Room thermostat can be connected to the boiler 22 ACCESSORIES The ATTAC...

Page 84: ...CE PARAMETERS SETTINGS A service code is required to set service parameters Click on General Settings pic 91 WARNING Do not modify the boiler service parameters unless you have the privi lege to do so...

Page 85: ...84 Entry into Service parameters Pic 92 Access to Service parameters Pic 93 After entering the service technician s access code the advanced boiler parameters are made available...

Page 86: ...85 Service parameters page 1 Pic 94...

Page 87: ...ful further ignition attempts are made The number of ignition attempts is entered here Maximum Power the maximum power the burner should achieve Maximum Ignition time indicates the maximum acceptable...

Page 88: ...me after ignition is the time it takes for forming of a stable layer of pellets in the burner followed by an increase in performance Max Combustion time the maximum continuous burning time of the pell...

Page 89: ...n it is the burner fan power that will be during the burning time after ignition Pellet Fan during burnout the fan performance during the burnout phase Pellet Fan max power only the manufacturer or se...

Page 90: ...er which it will be switched on again Power regulator worktime control time PID control model set from factory Power regulator P Part proportional part of PID control model set from factory Power regu...

Page 91: ...h the actu al boiler temperature has to decrease compared to the set temperature in order to restart the exhaust fan Exhaust temperature start heating is the flue gas temperature according to which th...

Page 92: ...ach the flue gas temperature of the wood igniter If this temperature is not reached the boiler will be shut down and the boiler report a fuel shortage Exhaust temperature max power the flue gas temper...

Page 93: ...will control the combus tion process at maximum power Oxygen setpoint min power the oxygen value by which the boiler will control the combus tion process at minimum power Difference boiler temperature...

Page 94: ...y with a rated thermal output not exceeding 500 kW Terminology requirements testing and marking CSN 06 1008 1997 Fire safety of thermal equipment STN EN 60335 1 ed 2 2013 Electrical appliances for hou...

Page 95: ...basis for the processing of your personal data We will process your personal data for the following purposes and on the basis of the following legal bases 1 For the purposes of direct marketing which...

Page 96: ...purposes of fulfilling the ex tended warranty agreement We would not be able to fulfill our obligations under the ex tended warranty agreementproperly without these data Our legitimate interest and o...

Page 97: ...ss and the text I hereby raise an objection to the processing of my personal data for the purposes of direct marketing and your signature We always inform you about the accepting your requestwithout d...

Page 98: ......

Page 99: ......

Page 100: ...s temporary subject to change without notice and for informational purposes only Variations in product visual display are possible and may not match the offer and range of equipment for different mark...

Reviews: