Service parameters, page 3
Pic. 96
Photocell Fier off
– if the value of the flame intensity in the burner drops below this value, the
boiler evaluates that the flame has been lost in the burner, i.e. the process of burning is stopped.
The boiler evaluates this as an error
Difference boiler temperature Start -
determines how many degrees the boiler temperature
must fall below the set temperature so that the boiler is switched on again (only in PELLET
mode)
Burn-On time after ignition -
is the time it takes for forming of a stable layer of pellets in the
burner, followed by an increase in performance
Max. Combustion time-
the maximum continuous burning time of the pellet burner after which
time the burner is automatically cleaned
Exhaust fan Regulation max. Power -
determines the maximum output of the boiler exhaust
fan in PELLET mode
Exhaust fan Regulation min. Power -
determines the minimum output of the boiler exhaust
fan in PELLET mode
Burn-Off time
– is the maximum time after which, even if the pellets have not burnt in the
burner, the burner will be cleaned
Feeding cycle at 100% power -
is the pellet feeding cycle to the burner
Summary of Contents for AWP 25
Page 1: ...www attack sk ATTACK WOOD PELLET Instruction for use EN EN 06 2019...
Page 2: ......
Page 30: ...29 Coming out from Test menu 2 Pic 15 Coming out from Test menu 3 Pic 16...
Page 51: ...50 Message Missing Fuel Pic 49 Burn Out mode Pic 50...
Page 72: ...71 New Software Update Pic 82...
Page 86: ...85 Service parameters page 1 Pic 94...
Page 98: ......
Page 99: ......