37
9.
After choosing WOOD mode there are displayed Start Options where we choose manual ig-
nition (pic. 26). The exhaust fan will start to work and the wood will be prepared for lighting
up.
Lighting up the wood in the wood gasification part:
Pic. 26
1 - manual starting (ignition), 2 - automatic starting, 3 – time of glowing the heating coil (by au-
tomatic ignition) , 4 – delay timeof ignition (by automatic ignition), 5 – output coils works on (by
automatic ignition)
10.
Light the pellets on the bottom through the middle door by a lighter. Keep themiddle door
partly open, until the cardboard and the wood chips light up (approximately for 5 min) and
the chimney gets the draught. Afterwards, close the door. This way of heating is very quick
and it enables to heat the boiler up without any smoke. Through the pivot control opening
on the bottom door you can watch the flame created by the process of gasification. Close the
main door after verifying, that the flame was created and the boiler correctly gasifies.