Atsumi Electric IR36E Installation Instructions Manual Download Page 7

12

DIMENSIONS

Unit : inch(mm)

PASSIVE INFRARED DETECTOR

IR36E

9 ~ 18 VDC

25 mA (Max)

-4 ~ +122

°

F (-20 ~ +50

°

C), RH35 ~ 95%, Non-condensing

-4 ~ +140

°

F (-20 ~ +60

°

C), RH35 ~ 95%, Non-condensing

Ø 20 m (Ø 66 ft.)  360

°

132 zones (66 pairs)

Passive Infrared

- Warm-up (30 seconds):   Flickers
- Alarm:                        Lights
- Alarm Memory:          Lights

- Self-Diagnostic:         Flickers

Å@

Form 1a/1b

- 3 seconds
- 30 VDC, 0.1A for Resistive Loads

- 6.0 

±

1

Å@

Form 1b

- Open while the sensor is detached from the base.
- 30 VDC, 0.1A for Resistive Loads

- 0.5 

±

0.5

1 ~ 6.6ft./sec. (0.3  ~ 2.0 m/sec.)

Over 2.7

°

F(1.5

°

C) difference against stable background

at 3.3ft.(1m)/sec.under Environmental condition of 95

°

F(35

°

C)

16.8

°

  vertically

Ceiling, Indoor, Mounting height 8 ~ 20ft. (2.5 ~ 6m)

230 g

13

SPECIFICATIONS

Description

Model

Power input

Current draw

Operating Temperature & Humidity

Storage Temperature & Humidity

Coverage

Detecting zone

Detection method

LED indication

Alarm output

Tamper

Detectable Speed

Sensitivity

Adjustable mirror range

Mounting

Weight

*Specifications and design are subject to change without prior notice.

Ø5.71

(Ø145)

2.56

(65)

Ø 0.94  Wiring hole
(Ø 24)

0.18

(45)

Ø 0.34

(Ø 8.6)

2.63

(66.7)

25

°

7

Summary of Contents for IR36E

Page 1: ...y must be cut off during installation Keep power between 9 18 VDC anytime Attention Avoid intense shock and vibration After installation and setup make sure of performance and appropriate coverage of...

Page 2: ...5 open when power is not supplied N C opens when the sensor unit is removed Contact Rating 30VDC 0 1A for Resistive Loads Please see 6 Functions for details 9 18 VDC Function Wire size 0 3mm2 or 0 65...

Page 3: ...se unit 2Mount the base unit on ceiling and connect the wire to the unit 3Perform initial setup Please see 7 Initial setup for details 4Determine coverage Please see 8 Determining Coverage for details...

Page 4: ...indicate the memory while both terminals are connected 4 Memory will be reset and the LED will be turned off when power is cut off or both terminals are disconnected 3 SELF DIAGNOSTIC CIRCUIT function...

Page 5: ...heir area numbers are indicated on the label of the base unit Each arrow is centered in each coverage of 120 degrees and its number stands for each one of three 3 areas The same numbers are also marke...

Page 6: ...other unit s Self Diagnostic circuit is activated 11 COVERAGE Side View The unit must be installed so that intruders will cross field of view Failure of this doing may end up mis alarm When the covera...

Page 7: ...tive Loads 0 5 0 5 1 6 6ft sec 0 3 2 0 m sec Over 2 7 F 1 5 C difference against stable background at 3 3ft 1m sec under Environmental condition of 95 F 35 C 16 8 vertically Ceiling Indoor Mounting he...

Page 8: ...movement of an intruder and activates an alarm control panel Being only a part of a complete system we can not take responsibility for any damages or other consequences resulting from an intrusion AT...

Reviews: