Atsumi Electric IR36E Installation Instructions Manual Download Page 6

10

TROUBLE SHOOTING

SYMPTOM

The unit does not detect or LED
does not light.

The unit detects occasionally.

False Alarm (The unit detects
against nobody.)

LED lights with no alarm output.

LED lights with no alarm output. (In
case COM and NC are used for
alarm output.)

LED flickers sending alarm output.

POSSIBLE CAUSE

Blocked by partitions or other objects.

Dip switch 2 is OFF.

Intruder does not cross field of view.

Installed too close to electrical noise or
wired too close to the power or power
line.

Sudden temperature fluctuation

Direct sunlight or intense headlight

Sensor and Base unit are not securely
fixed.

Controller is not armed.

Disconnection, Poor connection, Short
or Poor insulation of the wire

Alarm output is connected in parallel with
that of other unit(s).

Self-Diagnostic circuit is activated.

11

COVERAGE

Side View

The unit must be installed so that intruders
will cross field of view.  Failure of this doing
may end up mis-alarm.

When the coverage is blocked with partitions
or furniture, the unit does not detect over
them.   Move the unit or install two or more
units to maintain the desired coverage.

Top View

Mounting height 20ft.(6m)

Mounting height 8ft.(2.5m)

REMEDY

- Remove blocking objects.
- Reset coverage.

Turn the switch to ON.

Reset coverage.

- Install in other place.
- Change the wiring route.

- Remove heat source.
- Reset coverage.

- Reset coverage.
- Block the light using  blinds, etc.

Make sure to fix them together.

Arm the controller.

Check with Tester, then fasten terminal
screws securely.

- Wire the outputs in series.
- Connect one unit only in one loop.

Replace the unit.

66ft.

(20m)

2.3ft.

(0.7m)

A-A

A-A

B-B

B-B

3ft.

(0.9m)

33ft.

(10m)

33ft.

(10m)

0

33ft.

(10m)

33ft.

(10m)

0

33ft.

(10m)

33ft.

(10m)

0

3.6ft.

(1.1m)

33ft.

(10m)

33ft.

(10m)

0

6

Summary of Contents for IR36E

Page 1: ...y must be cut off during installation Keep power between 9 18 VDC anytime Attention Avoid intense shock and vibration After installation and setup make sure of performance and appropriate coverage of...

Page 2: ...5 open when power is not supplied N C opens when the sensor unit is removed Contact Rating 30VDC 0 1A for Resistive Loads Please see 6 Functions for details 9 18 VDC Function Wire size 0 3mm2 or 0 65...

Page 3: ...se unit 2Mount the base unit on ceiling and connect the wire to the unit 3Perform initial setup Please see 7 Initial setup for details 4Determine coverage Please see 8 Determining Coverage for details...

Page 4: ...indicate the memory while both terminals are connected 4 Memory will be reset and the LED will be turned off when power is cut off or both terminals are disconnected 3 SELF DIAGNOSTIC CIRCUIT function...

Page 5: ...heir area numbers are indicated on the label of the base unit Each arrow is centered in each coverage of 120 degrees and its number stands for each one of three 3 areas The same numbers are also marke...

Page 6: ...other unit s Self Diagnostic circuit is activated 11 COVERAGE Side View The unit must be installed so that intruders will cross field of view Failure of this doing may end up mis alarm When the covera...

Page 7: ...tive Loads 0 5 0 5 1 6 6ft sec 0 3 2 0 m sec Over 2 7 F 1 5 C difference against stable background at 3 3ft 1m sec under Environmental condition of 95 F 35 C 16 8 vertically Ceiling Indoor Mounting he...

Page 8: ...movement of an intruder and activates an alarm control panel Being only a part of a complete system we can not take responsibility for any damages or other consequences resulting from an intrusion AT...

Reviews: