PARTS DESCRIPTION

1

Sensor unit

2

Base unit

3

LED for Alarm/Memory(Red)

4

Knockout

5

Lock screw

6

Terminals

7

Dip switches

4

1.  Terminals

WIRING

Description

1

Power (+)

2

Power (-)

3

Alarm output (NC)

4

Alarm output (COM)

5

Alarm output (NO)

67

Tamper

8

Alarm memory

• 

3

 - 

4

: Form B, N.C.

• 

4

 - 

5

: Form A, N.O.

• Contact Rating :30VDC,0.1A for Resistive Loads

• Both ‘‘

3

 - 

4

’’and ‘‘

4

 - 

5

’’open when

  power is not supplied.

• N.C. opens when the sensor unit is removed.

• Contact Rating : 30VDC, 0.1A for Resistive

   Loads

 Please see‘‘ 6. Functions’’ for details.

9 - 18 VDC

Function

Wire size

0.3mm

2

 or Ø 0.65(AWG22)

0.5mm

2

 or Ø 0.8(AWG20)

*When two or more units are used on one wire, the maximum distance is obtained by dividing the above distance by the

*

number of units.

Distance at 12 VDC

850 m

1,300 m

2.  Wire Distance

3. Wiring samples
   (1) 1 detector (

3

 - 

4

, Form B used)

1

Sensor unit

2

Base unit

Power
  Output

Alarm
  Input

Tamper

Controller

Detector

2

Summary of Contents for IR36E

Page 1: ...y must be cut off during installation Keep power between 9 18 VDC anytime Attention Avoid intense shock and vibration After installation and setup make sure of performance and appropriate coverage of...

Page 2: ...5 open when power is not supplied N C opens when the sensor unit is removed Contact Rating 30VDC 0 1A for Resistive Loads Please see 6 Functions for details 9 18 VDC Function Wire size 0 3mm2 or 0 65...

Page 3: ...se unit 2Mount the base unit on ceiling and connect the wire to the unit 3Perform initial setup Please see 7 Initial setup for details 4Determine coverage Please see 8 Determining Coverage for details...

Page 4: ...indicate the memory while both terminals are connected 4 Memory will be reset and the LED will be turned off when power is cut off or both terminals are disconnected 3 SELF DIAGNOSTIC CIRCUIT function...

Page 5: ...heir area numbers are indicated on the label of the base unit Each arrow is centered in each coverage of 120 degrees and its number stands for each one of three 3 areas The same numbers are also marke...

Page 6: ...other unit s Self Diagnostic circuit is activated 11 COVERAGE Side View The unit must be installed so that intruders will cross field of view Failure of this doing may end up mis alarm When the covera...

Page 7: ...tive Loads 0 5 0 5 1 6 6ft sec 0 3 2 0 m sec Over 2 7 F 1 5 C difference against stable background at 3 3ft 1m sec under Environmental condition of 95 F 35 C 16 8 vertically Ceiling Indoor Mounting he...

Page 8: ...movement of an intruder and activates an alarm control panel Being only a part of a complete system we can not take responsibility for any damages or other consequences resulting from an intrusion AT...

Reviews: