Atsumi Electric IR36E Installation Instructions Manual Download Page 3

(2) 2 detectors (

3

 - 

4

, Form B used)

To maintain stable performance, use the same kind of wire for all purposes, Power, Tamper, Alarm and Alarm memory.

Do not supply power until all wiring is completed.

Connect the unit to a UL listed power supply or control panel capable of providing stand-by power for at least 4 hours.

Refer to the National Electrical Code, NFPA70.

5

INSTALLATION

1

Loosen the lock screw then turn the sensor unit counter-

clockwise to remove it from the base unit.

2

Mount the base unit on ceiling and connect the wire to the

unit.

3

Perform initial setup.   Please see ‘‘ 7. Initial setup’’ for details.

4

Determine coverage.   Please see ‘‘ 8. Determining Coverage’’  for details.

5

Mach direction of both arrows then align V-shaped protrusion A of the sensor unit with Mark B of the base unit.   Then turn the

sensor unit clockwise until matching Mark C.

6

Mount the sensor unit to the base unit using the lock screw.

Install the unit so that intruders will cross field of view.   Please see Section ‘‘11 Coverage’’ for details.

Detector

Detector

Power
  Output

Alarm
  Input

Tamper

Controller

Wiring hole

Arrows

Mark B

Mark C

V-shaped protrusion A

Knockout

3

Summary of Contents for IR36E

Page 1: ...y must be cut off during installation Keep power between 9 18 VDC anytime Attention Avoid intense shock and vibration After installation and setup make sure of performance and appropriate coverage of...

Page 2: ...5 open when power is not supplied N C opens when the sensor unit is removed Contact Rating 30VDC 0 1A for Resistive Loads Please see 6 Functions for details 9 18 VDC Function Wire size 0 3mm2 or 0 65...

Page 3: ...se unit 2Mount the base unit on ceiling and connect the wire to the unit 3Perform initial setup Please see 7 Initial setup for details 4Determine coverage Please see 8 Determining Coverage for details...

Page 4: ...indicate the memory while both terminals are connected 4 Memory will be reset and the LED will be turned off when power is cut off or both terminals are disconnected 3 SELF DIAGNOSTIC CIRCUIT function...

Page 5: ...heir area numbers are indicated on the label of the base unit Each arrow is centered in each coverage of 120 degrees and its number stands for each one of three 3 areas The same numbers are also marke...

Page 6: ...other unit s Self Diagnostic circuit is activated 11 COVERAGE Side View The unit must be installed so that intruders will cross field of view Failure of this doing may end up mis alarm When the covera...

Page 7: ...tive Loads 0 5 0 5 1 6 6ft sec 0 3 2 0 m sec Over 2 7 F 1 5 C difference against stable background at 3 3ft 1m sec under Environmental condition of 95 F 35 C 16 8 vertically Ceiling Indoor Mounting he...

Page 8: ...movement of an intruder and activates an alarm control panel Being only a part of a complete system we can not take responsibility for any damages or other consequences resulting from an intrusion AT...

Reviews: