2.4.1. Removing the sonotrode slide
(2)
1.
Press Reset to cut the tape. This opens
the arch.
2.
Shut down the machine.
3.
Release the spring (1) on the Sonotrode
slide.
4.
Remove the plug connection of the red
and black wire between the sonotrode
and generator carefully.
5.
Remove both screws (2) of the left
sonotrode guide.
6.
Push down the left guide and remove it
out of the unit.
7.
Rotate the Sonotrode slide slightly
counter-clockwise and remove it
carefully from the unit (you may have to
lift the arch bottom slightly).
2.4.2. Mounting the sonotrode slide
1.
Before mounting the sonotrode slide, lubricate both sides of the sonotrode slide, the cam follower and cutter.
2.
Place the sonotrode slide back in the unit.
3.
Slide in the left sonotrode guide back in the unit from below.
4.
Push the left guide together with the sonotrode slide all the way to the left side of the unit and tighten both
screws.
5.
Insert the tension spring (1).
6.
Reconnect the red and black sonotrode wire.
Note:
To reduce the electromagnetic disturbance, the red and black wire from the sonotrode have to be twisted.
Whenever possible, keep the sonotrdode wires out of the cable channel (separated from other wires).
2.5.
Sonotrode and generator
Note:
•
Sonotrode and Generator always need to be replaced as a set and not separately (it is possible, that a
damaged sonotrode would cause a new generator to fail again after only a few cycles).
•
sonotrode wires should only get replaced with original ATS-parts (these wires are more resistant against
mechanical wear and are built for the high frequency signals coming from the generator).
(1)
(2)