33
Filter unit or dryer unit
(sometime is built in) is
clog or poor drainage.
1. Check the filter unit.
2. Repair or replace the
dryer.
Tube for air is too long
that loss too much air.
1.
Enlarge the OD for
air tube, or shorten
the tube length.
2.
Add an air-reserve
tank.
The electronic
components damage
frequently
The area is too humid.
Always keep the door of
electrical control box
closed.
There is too much dust
on the electronic
components that cause
malfunction.
Always keep the door of
electrical control box
closed.
When the main power is
not stable.
Install a voltage
stabilizer.