Summary of Contents for MB52 Series

Page 1: ...MB52XX Modbus Gateway User Manual V 1 0 MB52XX Series Modbus Gateway User Manual V1 0 September 16th 2019 Atop Technologies Inc...

Page 2: ...or ease of navigation For example click on any item listed in the Table of Contents to go to that page Published by Atop Technologies Inc 2F No 146 Sec 1 Tung Hsing Rd 30261 Chupei City Hsinchu County...

Page 3: ...ecution All rights including rights created by patent grant or registration of a utility model or design are reserved Disclaimer We have checked the contents of this manual for agreement with the hard...

Page 4: ...gement Utility 14 4 2 Configuring through Web Interface 16 4 3 Configuring Automatic IP Assignment with DHCP 17 4 4 Web Overview 17 4 5 Network Configuration 18 4 6 Basic Settings 19 4 6 1 COM Setting...

Page 5: ...15 Modbus TCP Setting Page with TCP Master Operation Mode Selection 24 Figure 4 16 Slave ID Map Page with Slave ID Setting in Alias Mode 25 Figure 4 17 Slave ID Map Web Page with Slave ID Setting in i...

Page 6: ...ult Settings 13 Table 3 5 Other Default Settings 13 Table 6 1 Hardware Specification 40 Table 6 2 MB5201 MB5202 Pin Assignment for DB9 to RS 232 RS 422 RS 485 Connector 41 Table 6 3 MB5201 MB5202 Pin...

Page 7: ...1 3 Supported Platform This manual is designed for MB52XX Series Modbus Gateway and that series only 1 4 Manufacturers FCC Declaration of Conformity Statement NOTE This equipment has been tested and f...

Page 8: ...isting devices or controllers running Modbus serial protocol Modbus ASCII or Modbus RTU to an Ethernet network The MB52XX Series are standard Modbus gateways that convert packets between Modbus TCP an...

Page 9: ...terface between Modbus RTU ASCII host connected through Serial IP over Ethernet virtual communication port VCOM to Modbus RTU ASCII serial devices Figure 2 2 Use Cases of the MB52XX Series Modbus Gate...

Page 10: ...ged upon delivery Atop s utility software Device View and Serial Manager are obsolete and replaced by Device Management Utility Table 3 2 Description of Optional Accessories Optional Accessories Model...

Page 11: ...ppearance Front and Rear Panels The following figures show particular MB520X series device s front back side and top panels MB5201C Entry Level Semi Industrial Modbus Gateway MB5201 Industrial 1 Port...

Page 12: ...roduct Atop will not be liable for any damages to property or personal injuries resulting from the installation or overall use of the device Do not attempt to manipulate the product in any way if unsu...

Page 13: ...ameter Default Values Modbus Master TCP Settings TCP Master Mode TCP Master Port 502 Modbus Slave MB5201 MB5202 Mode RTU Slave Serial Configuration RS 232 9600 bps 8 data bits No parity bit 1 stop bit...

Page 14: ...detect your Modbus Gateway and list it on Device Management Utility s window Alternatively if you did not see your Modbus Gateway on your network press Rescan icon a list of devices including your Mo...

Page 15: ...is admin while the default password default After clicking on the Authorize button a notification window will pop up as shown in Figure 4 4 and some device may be restarted After the device is restart...

Page 16: ...herefore the device can be accessed by using a web browser for configuring by entering the device s IP address default IP address is 10 0 50 100 in the URL field of your web browser Figure 4 5 illustr...

Page 17: ...ically checkbox in the Network Setting dialog as shown in Figure 4 3 using Atop s Device Management Utility and then restart the device Once restarted the IP address will be configured automatically 4...

Page 18: ...automatically Figure 4 8 Network Web Page At the lowest box in Figure 4 8 you will have the DNS Settings box which allows you to set the IP addresses of Domain Name Server 1 DNS 1 and Domain Name Serv...

Page 19: ...ure the role of the serial device in your Modbus Gateway device and its serial communication parameters The term Operation Mode will be used to refer to the combination of role Master or Slave and the...

Page 20: ...ps Software Selectable Parity None Odd Even Mark or Space Data Bits 7 or 8 Stop Bits 1 or 2 Flow Control None Software Xon Xoff Hardware RTS CTS Receiver Resistor On or Off Apply to all Serial Ports c...

Page 21: ...of the devices connected through this VCOM port as shown in Figure 4 12 Its definition is the same to the one given in Section 4 6 2 Here the user can choose whether device conforms to a RTU or an AS...

Page 22: ...Box for Applying the Settings to All VCOMSs After finishing configuring the VCOM Settings click on Save Configuration button to save all changes that have been made A Save Successfully message will sh...

Page 23: ...ce will operate as a TCP Server that opens its TCP port to accept connections The TCP Master option will be described at the end of this section Remote IP Address This setting shows the IP address of...

Page 24: ...f the list to select all items and click remove Alternatively the Modbus TCP connection can be configured to run in TCP Master Operation Mode This means that the device will be a Modbus Master node an...

Page 25: ...e Slave Interface When a port is set to Modbus slave mode a slave interface will be created Select a radio button of a port number behind the Slave Interface which can be any one of the listed COM VCO...

Page 26: ...ve ID Settings box there is a list of mapping entries as shown in Figure 4 17 in which each line will summarize an Entry No a Modbus Protocol a Source a Slave ID Setting Mode and the Slave ID Range Vi...

Page 27: ...this box is not checked it means that SNMP is disabled Then the rest of the options will be disappeared as shown in Figure 4 18 If the SNMP option is enabled there can be three different views for SN...

Page 28: ...3 Password is the password for SNMP account for SNMP v3 Encrypt is a drop down box which allows the user to choose the encryption scheme for SNMP v3 The available options are None DES or AES The defau...

Page 29: ...B52XX Modbus Gateway User Manual Configuration and Setup Figure 4 20 SNMP Settings Web Page with SNMP Enabled and Version v1 v2c Figure 4 21 SNMP Settings Web Page with SNMP Enabled and Version Only v...

Page 30: ...tings When enabled an E mail alert will be sent to the designated E mail addresses in the SMTP Simple Mail Transfer Protocol Settings To setup an email alert function the user needs to configure the s...

Page 31: ...age that can trigger alert functions by checking the corresponding E mail boxes which are Cold Start is an event when power supply is interrupted Warm Start is an event when the device Restart functio...

Page 32: ...he first three anomalies above This will send out alerts to an SNMP Trap Server Note that to configure SNMP Trap Server please see Section 4 7 After the Alert Events setting is complete click on Save...

Page 33: ...the option to show all events by clicking the Show All Event button and the option to clear them all by clicking on Clear All Event button Figure 4 26 System Log Web Page 4 9 3 Data Log The log of Mo...

Page 34: ...Web Page 4 9 5 Time Date and time can be set manually or through Network Time Protocol NTP to automatically synchronize date and time of the Modbus Gateway with a Time Server Figure 4 29 shows the Ti...

Page 35: ...have been done A Save Successful message will show up with a hyperlink to restart the device as shown in Error Reference source not found Click the restart hyperlink to apply the changes Then a messag...

Page 36: ...e Web Console by clicking on the corresponding radio button Additionally the user can protect how the user accesses the device with a Reset Button Protect option by checking on either No or Yes radio...

Page 37: ...en click on the Import Configuration button to start the importing process After importing is complete the system will show a Save Successful message with a hyperlink to restart the device Click the r...

Page 38: ...umber will show up After a successful device s restart the web browser will be redirected to the Overview page as shown in Figure 4 7 Figure 4 33 Factory Default Web Page 4 10 Restart For some unexpec...

Page 39: ...MB52XX Modbus Gateway User Manual Configuration and Setup Figure 4 34 Restart Web Page...

Page 40: ...RP Telnet RFC2217 Serial Serial Interface RS 232 RS 422 RS 485 Software Selectable Default RS 232 Serial Connector MB5201 1 Serial Port TB 5 or DB 9 MB5202 2 Serial Ports TB 5 or DB 9 Serial Port Comm...

Page 41: ...ng Environmental Temperature Operations 40 C 70 C 40 F 158 F Storage 40 C 85 C 40 F 185 F Relative Humidity 5 95 55 C Non condensing 5 2 Serial port Pin Assignments 5 2 1 Pin Assignments for Serial In...

Page 42: ...lour Status Message RUN Green Blinking System is booted up and AP Firmware is running normally On System is booted up and not running AP Firmware Off System is still booting up or powered off LAN Oran...

Page 43: ...eimbursement Customers must always obtain an authorized RMA number from us before shipping the goods to be repaired When in normal use a sold product shall be replaced with a new one within 3 months u...

Page 44: ...Main Rd Indiranagar Bangalore 560038 India Tel 91 80 4920 6363 E mail Abhishek S atop in ATOP INDONESIA BRANCH Jopson Li Branch Director Wisma Lampung Jl No 40 Tomang Raya Jakarta Barat 11430 Indones...