MDSC-1000B
使用指南
15
flickers. Then the single metal sheet passes through the equipment under dynamic
conditions. Shortly press the “Confirm” key to save.
短按双张设定键,双张红色
LED
闪烁,双张片料动态过机,短按确定键保
存:
Shortly press the “Double-sheet Setting” key and the Double-sheet red LED
flickers. Then the double metal sheets pass through the equipment under dynamic
conditions. Shortly press the “Confirm” key to save.
长按返回键
3
秒,退出设置模式,进入工作模式:
Long press the “Return” key for 3s to exit the setting mode and enter the
working mode.
⑤
Under the setting mode (Long press the “Confirm” key for 3s.), shortly press
the “Single-sheet Setting” key, and at the time the “Single-sheet” green indicating
lamp flickers. The feeding control system normally conveys a metal sheet to pass
though the equipment (under dynamic conditions to pass through the equipment).
Shortly press the “Confirm” key to save, and the single-sheet dynamic learning is
completed.
⑥
Shortly press the “Double-sheet Setting” key and at the time the
“Double-sheet” red indicating lamp flickers. The feeding control system normally
convey two metal sheets that they are stuck together to pass through the equipment
(under dynamic conditions to pass through the equipment). Shortly press the
“Confirm” key to save and the double-sheet dynamic learning is completed.
⑦
Completing the setting: Long press the “Return” key for 3s, and the backlight
of the LCD is power off, which means the setting mode has been exited and the
working mode enters. So far, the setting has been completed and the detecting work
can be done.
Each time when the metal sheet has changed its specification or the
position of the feeding material appears big change, it is required to adjust the
equipment once more.