(iii) Manual setting (not a must) 

If you feel single-sheet or double-sheet detecting is not sensitive enough or too 

sensitive, then you can long press the “Confirm” key for 3s to enter the setting mode. 

After  that  shortly  press  the  “Confirm”  key,  then  the  numbers  beside  the 

“Single-sheet” on the LCD will flicker. At this time, you can press “Up” or “Down” 

key  to  adjust  the  sensitivity  value  of  the  single-sheet.  The  bigger  the  number,  the 

higher sensitivity. Then press the “Confirm” key to save the sensitivity setting of the 

single-sheet  and  turn  to  the  sensitivity  setting  for  the  double-sheet.  At  the  moment, 

the  numbers  beside  the  “Double-sheet”  on  the  LCD  flickers.  The  sensitivity 

adjustment of the double-sheet can be done as that of the single-sheet. After finishing 

adjustment,  press  the  “Confirm”  key  to  save.  And  during  the  sensitivity  adjustment 

for  the  single-sheet  or  double-sheet,  you  can  press  the  “Return”  key  to  exit 

adjustment and resume the previous sensitivity setting. 

Notes:  During  sensitivity  adjustment  for  the  single-sheet  or  double-sheet, 

that  is,  when  the  numbers  on  the  LCD  are  flickering,  the  seven  steps 

~

 

cannot  be  done.  Non-professionals  are  not  suggested  to  operate  the  manual 

sensitivity setting.

 

VII. Warranty agreement 

1. The warranty period for this product is 18 months and subject to the equipment’s 

bar code. If the product breaks down or appears damage under normal operation as 

described in the User Manual, our company shall take the responsibility of 

free-charge repair and maintenance of the product.

 

2. Within the warranty period, if the damage to the product is caused by the following 

statements, certain amount of repair and maintenance fees shall be charged.

 

● The damage to the product is due to wrong usage or at-will dismantlement, repair, 

maintenance and remolding of the product;

 

Summary of Contents for MDSC-1000B

Page 1: ...User Manual for MDSC 1000B Metal Double sheet Detector Atonm Guangzhou Intelligent Technology Co Ltd ...

Page 2: ...ess steel sheets etc and can effectively prevent double sheet or multiple sheets together being sent to the next process so as to avoid the damage to the equipment This product is composed of two parts detecting host and sensors This manual is mainly to describe the specifications properties and using methods etc of MDSC 10000B series metal double sheet detectors Before using the product please ca...

Page 3: ... product In case of loose connection the wrong input or output signals may be generated During usage it is not allowed to use any tool to contact the display panel Any damage to the panel due to over external force should be borne by the user To avoid being electric shocked please first cut off the power source before connecting the product to its power supply The input voltage of the product is D...

Page 4: ...PNP single and double sheet switch signal output maximum drive 50mA 48V 3 double sheet relay signal output Normally open maximum 1A 60VDC Note The switch signal output width of the single and double sheets is more than 50ms Testing materials Steel sheets iron sheets copper sheets aluminum sheets zinc plated sheets and stainless steel sheets etc Testing thickness 0 05 4 5mm for iron sheets copper s...

Page 5: ...ED display Items Content displayed Description Single sheet sensitivity 0 99 Adjusting the identifying sensitivity between zero sheet and single sheet adjustable under setting mode the bigger the number the higher sensitivity Double sheet sensitivity 0 99 Adjusting the identifying sensitivity between single sheet and double sheets adjustable under setting mode the bigger the number the higher sens...

Page 6: ...udy modes Then the LED screen is lighted and the electric control outputs of the NPN PNP RELAY are prohibited Shortly press it to confirm the current operation 2 Under setting mode Shortly press the Confirm key and the single sheet double sheet sensitivity can be chosen and set 3 Under study mode Shortly press the Confirm key and the current study data can be saved Return 1 Cancel the previous ope...

Page 7: ...ompleted 2 Under dynamic learning mode Shortly press the Single sheet Setting and the Single sheet LED will flicker At the time the feeding control system will convey one testing metal sheet After finishing the convey press the Confirm key to save Double sheet Setting 1 Under Auto adjustment mode Place double testing metal sheets and Shortly press the Double sheet Setting key and then the 3 LED la...

Page 8: ...host into it Then insert the fixing clumps at the hole opening position of the top and bottom sides of the host and tighten the screws 2 Installation of sensors It is suggested that the sensors for the metal double sheet detector be installed on the metal or plastic supports as shown in the diagram the transmitting port T is at the bottom and the receiving port R is at the top the working sides wi...

Page 9: ...3 4 5 Double sheet signal output of the Relay NO position maximum 1A 60V 6 7 8 NPN single sheet double sheet signal output maximum drive 50mA 48V PLC or Driving relay can be connected 9 10 11 PNP single sheet double sheet signal output maximum drive 50mA 48V PLC or Driving relay can be connected 12 13 14 Transmitting sensors T 12 connecting to the red terminal 13 connecting to the blue terminal an...

Page 10: ... 黑 Black 4 Electric control wiring diagram i Connection of PNP NPN ports to relays to realize various controls 单张 Single sheet 双张 Double sheet 单张 Single sheet 双张 Double sheet 主机 NPN 接口 Host NPN Ports 主机 PNP 接口 Host PNP Ports ii Connection of PNP NPN ports to PLC to realize various controls ...

Page 11: ...口 Host s PNP port 接 PLC 负极 V Connecting PLC Negative Pole V 接 PLC 单张 输入端 Connecting PLC single sheet input port 接 PLC 双张 输入端 Connecting PLC double sheet input port 主机 NPN 接口 Host s NPN port iii Outputs of RELAY ports to realize various controls COM 公共端 COM Common terminal NC 常闭 NC Normally close NO 常开 NO Normally open 双张信号 Double sheet signal 主机 RELAY 接口 Host s REALY Ports ...

Page 12: ...arlier and the metal sheets conveyed remain unchanged then the host can directly work Otherwise the setting should be done as the following procedures i Auto adjustment 返回 Return 确认 Confirm 自动调节 Auto Adjustment 零张设定 Zero sheet Setting 单张设定 Single sheet Setting 双张设定 Double sheet Setting 长按确认键 3 秒 短按自动调节键 单张 LED 闪烁 进入自动调节模式 Long press the Confirm Key for 3s Shortly press the Auto Adjustment Key the ...

Page 13: ...here the metal sheet being placed should be consistent with that made by the feeding control system as much as possible Shortly press the Single sheet Setting key and only until the Double sheet red indicating lamp flickers can the single metal sheet be moved away Then the single sheet adjustment has been completed Let the feeding control system convey two metal sheets together to the center of th...

Page 14: ...orts and missing inspections etc especially when the metal sheets appear up and down moving phenomenon during detecting it is difficult to control the dynamic learning Therefore suggest increasing dynamic learning after finishing the auto adjustment 返回 Return 确认 Confirm 自动调节 Auto Adjustment 零张设定 Zero sheet Setting 单张设定 Single sheet Setting 双张设定 Double sheet Setting 短按单张设定键 单张绿色 LED 闪烁 单张片料动态过机 短按确...

Page 15: ...e equipment under dynamic conditions to pass through the equipment Shortly press the Confirm key to save and the single sheet dynamic learning is completed Shortly press the Double sheet Setting key and at the time the Double sheet red indicating lamp flickers The feeding control system normally convey two metal sheets that they are stuck together to pass through the equipment under dynamic condit...

Page 16: ...ey to save And during the sensitivity adjustment for the single sheet or double sheet you can press the Return key to exit adjustment and resume the previous sensitivity setting Notes During sensitivity adjustment for the single sheet or double sheet that is when the numbers on the LCD are flickering the seven steps cannot be done Non professionals are not suggested to operate the manual sensitivi...

Page 17: ...used by the troubles out of the product itself such as the peripheral equipment problems 3 Should you find any problem in our service process please timely contact our company 4 If the customer purchased this product it means that the customer has agreed to this Warranty Agreement whose interpretation rights shall belong to Atonm Guangzhou Intelligent Technology Co Ltd Contact us Should you encoun...

Reviews: