Installation, Operation & Maintenance Guide

 

Matterhorn 1000/1002 

2

1-888-MY-AIR11        CAG-06-21-003        AtmosAir.com

Trademarks

Any brand names and product names included in this document are trademarks, registered trademarks, or trade names of their 
respective holders.

To the Holder of this Document

 

The contents of this document are current as of the date of publication. AtmosAir® reserves the right to change the contents 
without prior notice. 
 
In no event will AtmosAir be liable for any special, incidental, or consequential damages or for commercial losses even if AtmosAir 
has been advised thereof as a result of issue of this document.

WARNING

 

Failure to follow this warning could result in personal injury or death.

 

 

For installation you 

MUST:

 

■ Always disconnect all electrical power to the unit before handling any of the components, to the air handler before removing access 

panels, or to perform any maintenance activities.

 

■ Do NOT connect to the power before the installation is complete and personnel are aware of the imminent operation – secondary 

voltage to the ionization tube can be as high as 3,000 VAC.

 

■ Installation of AtmosAir equipment is not to be performed in areas with extreme conditions such as extreme heat or cold, or where 

water or condensing moisture can impact the system.

 

■ Carefully read this instruction booklet before beginning the installation.

 

■ Follow each installation or repair step exactly as shown and explained in this guide.

 

■ Observe all local, state, national, and international electrical codes.

 

■ Pay close attention to all warnings and caution notices given in this guide.

1. 

Before installing or servicing system, always turn off main power to system. 

Note: 

There may be more than one disconnect switch.

2. 

AtmosAir equipment must be installed with a proper ground. The electrical cable enclosed with your AtmosAir unit must be 
used as it has a special plug which provides a ground circuit for the equipment.

3. 

Always replace fuse with the same rating and type of fuse.

4. 

Failure to follow this caution may result in personal injury or product and/or property damage.

5. 

Although special care has been taken to minimize sharp edges in the construction of your unit, be extremely careful when 
handling parts or reaching into the unit.

6. 

Keep path clear near and in front of intake screen.

7. 

Do NOT block or obstruct the air flow over or around the ionizing tubes.

8. 

Do NOT touch ionizing tubes when power is on.

9. 

Do NOT operate outside of this range: -1°C to 49°C (30°F to 120°F).

10. 

Tube cleaning should be performed only when the power is disconnected.

11. 

The tubes require minimal cleaning with routine operation and maintenance. Longer operating cycles and reduced ionizing 
efficiency may indicate the need for cleaning or replacing tubes by your AtmosAir dealer or qualified installer.

Commissioning Statement

Do not 

commission new airhandlers after installation. All duct cleaning must be performed 

before

 the unit is installed.

Summary of Contents for Matterhorn 1000 Series

Page 1: ...s pure natural state where no pollution or contaminants exist while reducing energy use and emissions in the process AtmosAir com CAG 08 21 004 IMPORTANT Save this Document for Future Reference Warran...

Page 2: ...ch installation or repair step exactly as shown and explained in this guide Observe all local state national and international electrical codes Pay close attention to all warnings and caution notices...

Page 3: ...r otherwise All persons having access to the serviced premises should comply with applicable public health laws and guidelines issued by federal state and local governments and health authorities such...

Page 4: ...tallation 6 Mechanical Installation Continued 7 Duct Cut Out and Quick Change Plate Procedure 8 Duct Cut Out and Quick Change Plate Procedure Continued 9 Electrical Installation 9 Installation Dimensi...

Page 5: ...d for minimal maintenance efforts The 1000 1002 series has two components that require inspection and maintenance 1 AtmosAir Matterhorn 1000 series base unit components 2 Ionization tubes Because ther...

Page 6: ...d tight utilizing the blue cap DO NOT TWIST THE TUBE OR MOVE THE EMITTER SCREEN DO NOT OVER TIGHTEN THE TUBE Once the tube is secure return the conductor strap to its normal position and ENSURE SOLID...

Page 7: ...8 Units should be installed to allow easy access for maintenance Install units so that the 5 step power adjustment knob and status light are easily accessible and visible 9 In the case of the M1000 t...

Page 8: ...learance is recommended Procedure 1 Always measure for clearances for the tubes and wires prior to any other steps Then place the Q C P in the appropriate area 2 Holding the Q C P in place use a marke...

Page 9: ...pproximately 6 watts per tube An internal 1 25 amp slow blow fuse protects the unit Follow proper electrical procedures guidelines and codes for providing power to the systems including requirements f...

Page 10: ...ion Operation Maintenance Guide Matterhorn 1000 1002 10 1 888 MY AIR11 CAG 06 21 003 AtmosAir com Contact Us 1 888 MY AIR11 1 888 692 4711 Matterhorn 880 882 Installation Operation and Maintenance Gui...

Page 11: ...ES TO AFS 262 AIRSWITCH SHEET 1 OF 1 UNLESS OTHERWISE SPECIFIED SCALE 1 3 REV B DWG NO A SIZE TITLE NAME DATE COMMENTS FIELD WIRING DIAGRAM FOR CONNECTING MATTERHORN TO AFS 262 AIR SWITCH TO LINE VOLT...

Page 12: ...act Recommended Maintenance Procedures Visually check the performance of the system by checking the green lights on the individual units If the lights are on then the unit should be functioning proper...

Page 13: ...er degeneration of the dielectric material that causes the dielectric to fail and arcing to occur Inspect the tube for black dots indicating failed dielectric 7 If physical inspection has not revealed...

Page 14: ...use a flathead screwdriver to pop the fuse drawer towards you Above Matterhorn 1000 Ionization unit Here you will see there is one Ionization Tube installed towards the center of the device This shoul...

Page 15: ...ean and pure quality air that is typically found at higher mountain elevations AtmosAir s unique and proven air purification process significantly reduces mold controls the spread of bacteria and airb...

Page 16: ...IGATIONS OF CLEAN AIR GROUP HERIN ARE EXPRESSLY GRANTED IN LIEU OF ALL WARRANTS WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICUL...

Reviews:

Related manuals for Matterhorn 1000 Series