background image

BIONTECH Co., Ltd.

OPERATION MANUAL

Under-sink type

Korea Food and Drug Administration (KFDA) Manufacturing 

License No. 889 KFDA Product License No. 05-872

  Dedicated to runing water lines

* Read this manual carefully for proper use of the product. Keep the manual 

  in a safe place and refer to the manual whenever necessary.

* Our company will not be held responsible for any malfunction or accident 

  resulting from incorrect installation or improper handling.

Model : BTM-105DN

Summary of Contents for BTM-105DN

Page 1: ...License No 05 872 Dedicated to runing water lines Read this manual carefully for proper use of the product Keep the manual in a safe place and refer to the manual whenever necessary Our company will...

Page 2: ...potable water such as tap water The receptacle should be installed safely and correctly according to standard electricity and indoor cabling and wiring regulations Do not exceed the limit of the recep...

Page 3: ...kage may result Do not apply abnormal water pressure to the product If an outlet line is altered water leakage may result causing serious indemnification consequences If any water leakage occurs serio...

Page 4: ...sequences may ensue Do not hold the power plug with wet hands A partially inserted power plug may result in fire or electric shock Do not use a damaged power plug or loose receptacle This application...

Page 5: ...Accessories 1 Installation Reference Information Operation Precautions 2 Parts Drawings for Installation Development Drawing of Raw City Water Connection 3 Selecting Locations for Water Outlet Faucet...

Page 6: ...d in packing materials The following are the parts necessary for piping to the sink Reinforcing Plate Electric drill Pipe wrench or spanner Phillips Screwdriver Operation manual including warranty col...

Page 7: ...he cabinet A place where it is difficult to connect disconnect the power plug A place where leakage or condensed water may flow into the receptacle You may install the product as part of kitchen sink...

Page 8: ...ore drinking alkaline ionized water If you notice any health abnormalities after drinking alkaline ionized water or no improvement despite drinking for an extended period consult a physician or pharma...

Page 9: ...lt in overheating and eventual fire For power cord or power plug repair contact your purchase retailer or our head office Appearance of scratching Processed Near a heating device Bent excessively Bein...

Page 10: ...place anything on the product Prohibitory instruction Prohibitory instruction Prohibitory instruction Prohibitory instruction Prohibitory instruction Acidic ionized water Water discharged while the ab...

Page 11: ...ldren to prevent accidental ingestion The machine may malfunction or break down The container may become discolored or corroded Do not pour alkaline ionized water acidic ionized water or purified wate...

Page 12: ...12 2 Parts Drawing for Installation Check the positions of parts and accessories...

Page 13: ...t use to cut the edge of damaged hose for recombination after desorption How to connect caution 1 Connect adaptor to water pipe and combine fitting with entrance nipple of tap water of BTM 105D 2 Comb...

Page 14: ...he hole should be 35mm Trim the hole with a file If the stainless steel product has no reinforcing plate or is one with thickness of 5mm or less an additional reinforcing plate should be added Drill a...

Page 15: ...rt the controlling faucet into the hole on the sink And insert the reinforcing plate into the end of stand for the controlling faucet Tighten the faucet with the fixing nut Make sure the center of the...

Page 16: ...Make sure the water supply hose to connect by the one touch fitting 4 Make sure insert the water supply elbow to until edge of part Secure a space for easy filter replacement Make sure the alkaline io...

Page 17: ...the product by pushing the POWER button select the purification function and drain about 10 liters of water about 5 minutes This is to remove any air bubbles and fine particles from the activated car...

Page 18: ...does not respond at all Is the connector of the control panel cord completely connected Is the acidic water hose bent Is water throughput too low Are all parts completely connected Is the connector o...

Page 19: ...r side 1 4 Standend Hose Electrolysis Ionized Water System main unit Left Alkaline outlet nipple 5 16 Hose Right Acidic outlet nipple 1 4 Hose Alkaline ionized water outlet faucet Acidic water outlet...

Page 20: ...based on the water flow of 1 5 m 0 5 The pH values of the alkaline and acidic ionized water may not fall into the range of the pH value instructed of the table above depending on the water quality and...

Page 21: ...p drinking the water and consult a doctor if you feel abnormality after drinking the water or if there is no alleviation of symptoms felt in the stomach even after continuously drinking the water Thos...

Page 22: ...e machine for 2 seconds after water supply begins Power supply is automatically cut off once taking of water ceases Audio notification Alkaline ionized Water on Process When the machine is powered up...

Page 23: ...e do not stop the machine for 2 seconds after water supply begins Audio Crystal Clear Water in Production When the machine is powered up and water begins to be supplied at the previously set step the...

Page 24: ...the machine by pushing the POWER button To protect the machine do not stop the machine for 2 seconds after water supply begins Audio notification Acidic ionized Water on Process When the machine is p...

Page 25: ...lamp will blink and the machine plays a melody If you supply water to the machine while performing the automatic cleaning operation the machine will repeat the process until cleaning is complete Even...

Page 26: ...It is difficult to describe the amount of the reagent other than two or three drops Set the machine at Step 5 and drain alkaline water for about 10 seconds before taking a sample The recommended sampl...

Page 27: ...onnector into the corresponding port Picture 5 3 Connect the electric plug and turn on the way supply control valve and let the water pass fluently Then If a unbranded filter is installed there will b...

Page 28: ...ing this metod the pH of the ionized water will be resume higher because the water is now coming in direct contact with the cleaned electrodes Symptom of calcium scale when whitish floating substances...

Page 29: ...29 How to use cleaning filter ACID ALK PU ACID ALK PU...

Page 30: ...ng it as the water for cooking fish the fishy smell will be eliminated making the fish taste better Liquors cocktails The liquors will be made highly mild and soft When making an ice cocktail using th...

Page 31: ...onized water is used for cleaning corridors and tiled floors the dusts of every nook and corner can be easily removed The acidic ionized water is also fast in drying so it is not sticky When cleaning...

Page 32: ...suitable for use in the machine Make sure to measure the pH level of your underground spring in advance If acidity is too high consult your distributor or our head office A small amount such as a cup...

Page 33: ...nant being filtered you should use the proper filters A genuine filter carries a clear Biontech logo Bubbles are created in the course of electrolysis You will see more bubbles right after filter repl...

Page 34: ...achine The filter indicator blinks 999 No control lamp lights up Depending on water quality the machine may shut down and stop supplying water to protect itself Wait about a minute and reuse the machi...

Page 35: ...ntaminants Replace the filters Warm ionized water is possible initially depending on room temperature This is not a problem Drain some water until the water becomes cool If there is no change after dr...

Page 36: ...any connecting part Is there leakage from any filter Is there leakage from the faucets on the control panel Is there leakage from the main unit Does the machine run in normal operation modes Does each...

Page 37: ...ates Cartridge Type 2 Stage Lifespan Indication by LCD KFDA Manufacturing License No 889 No 05 872 Chronic Diarrhea Intestinal Abnormal Fermentation Indigestion Gastric Hyperplasia Nonwoven fabric Gra...

Page 38: ...l item as designated Any other problem as a result of external causes Problem that occurred due to product serviced by an unauthorized person If a product handed over for repair was lost by the compan...

Page 39: ...BTM 105DN...

Page 40: ...ionization system Bion Tech Co Ltd Bion tech Co Ltd 298 15 Gongdan ro Geumjeong dong Gunpo si Gyeonggi do South Korea Tel 82 31 459 3853 Fax 82 31 429 3859 E mail btm biontech biz http www bion tech c...