Installation, Operation & Maintenance Guide

 

AtmosSmart 

2

1-888-MY-AIR11        CAG-06-21-003        AtmosAir.com

Trademarks

Any brand names and product names included in this document are trademarks, registered trademarks, or trade names of their 
respective holders.

To the Holder of this Document

 

The contents of this document are current as of the date of publication. AtmosAir® reserves the right to change the contents 
without prior notice.

In no event will AtmosAir be liable for any special, incidental, or consequential damages or for commercial losses even if AtmosAir 
has been advised thereof as a result of issue of this document.

WARNING

 

Failure to follow this warning could result in personal injury or death. 

 

Disconnect all electrical power to the air handler before removing access panels or to perform any maintenance activities. 
Disconnect power to the AtmosAir units. 

 

Before installing or servicing system, always turn off main power to system. There may be more than one disconnect switch. 

 

AtmosAir equipment must be installed with a proper ground. The electrical cable enclosed with your AtmosAir unit must be used 
as it has a special plug which provides a ground circuit for the equipment. 

 

Always replace fuse with the same rating and type of fuse.

 

Failure to follow this caution may result in personal injury or product and/or property damage. 

 

Although special care has been taken to minimize sharp edges in the construction of your unit, be extremely careful when handling 
parts or reaching into the unit.

 

Keep path clear near and in front of intake screen

 

■ Do not block or obstruct the air flow over or around the ionizing tubes

 

Do not touch ionizing tubes when power is on

 

Do not operate outside of this range 30°F – 120 °F (-1°C – 49 °C).

 

Tube cleaning should be performed only when the power is disconnected.

 

The tubes require minimal cleaning with routine operation and maintenance. Longer operating cycles and reduced ionizing 

efficiency may indicate the need for cleaning or replacing tubes by your AtmosAir dealer or qualified installer.

How to Contact Us: 

If you need help, please contact an  

AtmosAir Representative for technical assistance.

Commissioning Statement

Do not 

commission new airhandlers after installation. All duct cleaning must be performed 

before

 AtmosSmart is installed.

Summary of Contents for AtmosSmart

Page 1: ...to its pure natural state where no pollution or contaminants exist while reducing energy use and emissions in the process AtmosAir com CAG 06 21 003 IMPORTANT Save this Document for Future Reference W...

Page 2: ...nd The electrical cable enclosed with your AtmosAir unit must be used as it has a special plug which provides a ground circuit for the equipment Always replace fuse with the same rating and type of fu...

Page 3: ...al Product Description 6 Mode of Operation 7 02 INSTALLATION 8 03 STEP BY STEP INSTALLATION INSTRUCTIONS 11 Installing AtmosAir 500 Series in a Duct 11 04 MONITORING DISPLAY INSTALLATION 12 05 ATMOSSM...

Page 4: ...Air Flow Sensor Differential Pressure Switch Optional Must be Ordered Control Capacity Up to 8 AtmosAir Ionization Systems Standard Unit 2 BPI Requires AtmosMultiplier 4 with Optional AtmosEXTender A...

Page 5: ...ing oxygen molecules are ionized which aid in cleaning indoor air General Product Description AtmosSmart is an integrated sensor array designed for installation in the RETURN duct of a typical HVAC ai...

Page 6: ...determining occupancy O3 Ozone HCHO Formaldehyde and PM Particulate Matter The IAQ readings can be output by attaching an HDMI capable display Display is accessible from a HDMI port located in the Se...

Page 7: ...lter if present or the AHU itself 02 INSTALLATION The Sensor Array is housed in a doubly insulated hi impact plastic enclosure which is placed in the duct work or AHU If placed in the duct a 3 8 8 cm...

Page 8: ...CH xxx BEND TWO PLACE DECIMAL xxx THREE PLACE DECIMAL APPLICATION USED ON NEXT ASSY PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ATMOSAIR SOLUTIONS AN...

Page 9: ...above The sensor head reads multiple indoor air quality IAQ data sets in real time by sensing air properties in the Return Air system This configuration allows the sensor to adjust IAQ based on deman...

Page 10: ...tallation recommendations Each AtmosSmart enabled 500 series Matterhorn Series unit has an AtmosComms2 controller module integrally installed These controller modules communicate with the sensor array...

Page 11: ...om of the duct A mounting bracket is optional The display shows real time data and is read only It may be folded up out of the way A HDMI port is also provided in the Sensor Body A large remote monito...

Page 12: ...e supplied ethernet cable between the jack on the AtmosSmart unit to the AtmosComms2 controller Note This is the only jack on the AtmosComms2 system mounted under the ionizer that could receive this c...

Page 13: ...There are no user serviceable parts inside the sealed Sensor module Sensors will need to be replaced recalibrated generally after 2 calendar years Certified AtmosAir dealers will coordinate sensor mai...

Page 14: ...NS OF CLEAN AIR GROUP HERIN ARE EXPRESSLY GRANTED IN LIEU OF ALL WARRANTS WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR...

Reviews: