Atmos EasySolar Installation Instructions Evacuated Tube Collector
8
4 Installation
4.1
Safety & insulation
Before you start work consider your own safety and that of others.
•
The EasySolar hot water system has electrical parts. Apart from the adaptor which
plugs into the 240V socket, these parts are all low voltage (12V) and therefore
perfectly safe. However it is advisable to take care not to damage any electrical
insulation and to avoid electrical parts becoming wet.
•
The heat exchanger and the flexible connecting pipes for domestic water are subject
to mains water pressure and can become hot. For this reason the flexible connecting
pipes for domestic water need to be insulated. Insulation for these pipes is included in
the assembly kit. The insulation must extend over the connections to the tank. Secure
the insulation with tape. Ensure that the tank and connecting pipes have cooled down
before any maintenance work is undertaken. The tank and connecting pipes can be
cooled down by drawing off hot water.
•
The pipes connecting the storage tank and the collectors can also become hot. The
red flow pipe needs to be insulated along its full length. Insulation for this pipe is
included in the assembly kit. Ensure that the pipes have cooled down before any
maintenance work is undertaken.
•
Assemble all components according to the installation instructions and avoid
components getting damaged during installation or subsequent use.
•
Put in place sufficient safety measures when working on the roof. Use scaffolding if
necessary.