ICE50 User Guide
8-1
Rev. 2523A–AVR–11/02
Section 8
Troubleshooting
The troubleshooting guide gives advise if errors occurs.
8.1
Troubleshooting
Guide
LEDs
– Red Power LED does not turn on. See Power Supply Trouble
– Multi color LED turns Red (error led lights up). See Configuration error
– Green LED does not light up. Start AVR Studio and try to change part.
Power Supply Trouble
– Check that power supply is connected
– Check for wrong polarity
– Check that the power source is not too weak
– Power Switch doesn't work
Configuration Error
– Not all modules have signed on. See ICE Status. Check if a module is
missing. A module not signed on will report a zero in the version field.
Communication Errors
– Check that the serial cable is connected.
– Check that the POD is properly connected. See Inserting POD into POD Bay
– Can't establish communication. Check if other equipment has control over the
COM port, IrDA etc.
– Cycle power and restart AVR Studio
– Do no use serial port I/O card or USB to serial adapter
– USB communication is not yet supported
Summary of Contents for ICE50
Page 1: ...ICE50 User Guide ...
Page 2: ......
Page 10: ...Preface 1 4 ICE50 User Guide 2523A AVR 11 02 ...
Page 14: ...Introduction 2 4 ICE50 User Guide 2523A AVR 11 02 ...
Page 48: ...Configuring AVR Studio 5 10 ICE50 User Guide 2523A AVR 11 02 Figure 5 11 ICE Staus Window ...
Page 52: ...Configuring AVR Studio 5 14 ICE50 User Guide 2523A AVR 11 02 Figure 5 15 Version Information ...
Page 70: ...Trace 7 16 ICE50 User Guide 2523A AVR 11 02 ...