Power
Requirements
The Probe and parts of the POD are powered by the target application power system.
The dynamic power requirements of the Probe/POD will not differ significantly from the
power requirements of the actual device. See below for power requirements. The static
power requirement for the POD is listed in Table 3-6. The target power system must be
dimensioned to tolerate this current consumption.
Note:
The Digital I/O drive capabilities of the ICE50 POD differ slightly from what can
be expected in the actual device. For details on the Digital I/O drive capabilities
compared to the actual device, please see the Digital I/O section of the POD
description.
Table 3-5. Power Requirements
Power Requirements
Power Voltage Requirements
9 - 15 VDC
Power Consumption
< 20 W
Target Application Voltage Range
2.7 - 5.5 V
Table 3-6. Target Voltage
Target Voltage
ICE50 (POD/Probe) current consumption from Target Application,
Normal (Typical)
Worst Case
2.5V
5 mA
7 mA
3.3V
20 mA
30 mA
5.0V
85 mA
125 mA
5.5V
110 mA
165 mA
Summary of Contents for ICE50
Page 1: ...ICE50 User Guide ...
Page 2: ......
Page 10: ...Preface 1 4 ICE50 User Guide 2523A AVR 11 02 ...
Page 14: ...Introduction 2 4 ICE50 User Guide 2523A AVR 11 02 ...
Page 48: ...Configuring AVR Studio 5 10 ICE50 User Guide 2523A AVR 11 02 Figure 5 11 ICE Staus Window ...
Page 52: ...Configuring AVR Studio 5 14 ICE50 User Guide 2523A AVR 11 02 Figure 5 15 Version Information ...
Page 70: ...Trace 7 16 ICE50 User Guide 2523A AVR 11 02 ...
Page 72: ...Troubleshooting 8 2 ICE50 User Guide 2523A AVR 11 02 ...