AT-ANC-108D
14
IP Configuration
Resetting to Factory Defaults
The AT-ANC-108D is shipped with DHCP enabled. Once connected to a network, the DHCP server (if available), will
automatically assign an IP address to the unit. AMS is recommended to configure IP settings of the AT-ANC-180D.
If a static IP address is desired, the unit can be switched to static IP mode. The default static IP address of the AT-
ANC-108D is
192.168.1.50
. Refer to
Accessing AMS (page 18)
for more information.
Resetting the AT-ANC-108D requires that the wallplate be removed. Refer to
Wallplate Installation (page 13)
for
more information. If no DHCP server is found after a factory-reset, then AT-ANC-108D will be assigned the default
static IP address of
192.168.1.50
.
1. Remove the wallplate from the AT-ANC-108D.
2.
Press and hold the upper-right button.
3.
Press the
Reset
button, using the end of a paper clip
or other pointed object. The upper-right button will
flash twice.
4. Release the upper-right button and the
Reset
button.
5. Reattach the wallplate to the AT-ANC-108D.
Basic Operation
Reset button
Upper-right button