42
PennEngineering • www.pemnet.com
Instruction Manual - RIV912
WARNING!!!
Tool setting and screw replacement must be carried out with the tool disconnected from air supply time.
SCREW REPLACEMENT
Between the casting and the nut, there must be a
distance of 1.5 mm for motor unscrewing.
NOTE: Hereunder instructions are relevant to KIT assembling and disassembling.
TO UNSCREW THE KIT HOLDER QUICK RING
Tool setting and screw replacement must be carried out with the tool disconnected from air supply time.
Press small buttons with two
fingers, pushing them inside
the hole while simultaneously
unscrewing the ring.
TO REPLACE SCREWS:
Unscrew the toothed ring 1 from the tool. Insert joint 2. Insert screw 3. Insert screw adapter 4. Screw the toothed ring 1 making
sure that the screw (or tie rod) rotates, then try and find the most suitable joint (see intended ring). Screw on 5 and 6.