6
B. Equipment storage and installation requirements.
The equipment should be stored or installed in a shady, normal temperature,
ventilated and dry place.
C. The equipment should be unloaded and transferred by forklift.
D. SPECIFICATIONS OF CONCRETE
(See Fig. 6)
Concrete must adhere to the specifications listed below, failure to do so
may result in lift and/or vehicle falling.
1. Concrete must be thickness 4
”
minimum, without reinforcing steel bars, and
must be completely dry before lift installation.
2. Concrete must be in good condition and must be of test strength 3,000 psi
(210kg/cm²) minimum.
3. Floors must be level with no cracks or holes.
E. POWER SUPPLY
220volt single phase source on a 30amp breaker with minimum of 10 gauge
wire running to the power unit. Operating voltage range is 208v-230v.
Fig.6
Concrete intensive must be
3,000psi (210kg/cm²)
¾”
Fig.5
4
”