29
Connection Step
(See Fig. 42)
a. Power supply line (
L1, L2, L3
) connected with terminals
L1, L2, L3
of AC
contactor respectively.
b. Wire
12#
(
brown wire
)
of limit switch connected with terminal
4#
of control
button; Wire
11#
(blue wire) connected with
terminal
A1
of AC contactor, Earth
wire( yellow and green wire) of limit switch connected with the terminal earth
wire of the motor.
C. Terminal
3#
of control button connected with terminal
L1
of AC contactor.
Fig. 42