Medium temperature
(°F)
Correction factor for maximum working pressure of
the compensator
122
1
176
1
185
0.92
194
0.83
203
0.75
212
0.67
221
0.6
230
0.54
Torque values
Compensator bolts should be torqued in 3 successive steps
• Step 1: Hand-tighten each bolt.
• Step 2: Torque the bolts crosswise up to the value mentioned in the table below and allow a
stabilization period of 30 minutes before moving to step 3.
• Step 3: Torque the bolts crosswise up to the value mentioned in the table below.
• Mind the parallelism of the sealing.
• Excessive torque will damage the sealing.
DN
(inch)
Step 1
Step 2
(lbfin)
Step 3
(lbfin)
2 – 3
hand tight
443
708
4 – 12
hand tight
443
885
14 – 20
hand tight
443
1551
Do's and don'ts
The supplied compensators are NOT designed:
• to carry the weight of the mounted customer pipe end.
• to work as a damper for unanchored pipe ends.
• to carry the thrust forces of the compressed air.
Therefore, adequate supporting and anchoring of the customer pipe end should be foreseen to
avoid compensator damage.