13
I
NSTRUCTION MANUAL
OPERATING INSTRUCTIONS
I
NSTRUCTIONS FOR PARKING AND TOWING
1. Before towing the compressor, ensure that the towing equipment
of the vehicle matches the towing eye. The height of the towing
device of the vehicle must be 800 ± 150 mm (31.2 ± 5.9 in).
2. Place the compressor as level as possible; however, it can be
operated temporarily in a slant position not exceeding 15 ¡.
3. Never move the compressor with air hoses connected to the air
outlet valves.
4. Always apply the hand brake when parking the compressor.
5. Always lift the unit using the lifting eye. The lifting eye is
provided on top of the compressor under a small door. Open the
door from the outside of the compressor and fix the hook of the
hoist to the lifting eye. Lifting acceleration and retardation shall
be kept within safe limits.
Helicopterlifting using the lifting eye is not allowed.
B
EFORE STARTING
1. Check the engine and compressor oil levels. Check the engine
coolant level. Check the fuel level and top up if necessary.
2. Drain water and sediment from the fuel filters.
3. Empty the air filter dust traps.
4. Attach the air line(s) to the closed air outlet valve(s). Connect
the safety cable and do not exert external force on the outlet
valve(s)
S
TARTING
1. Press the
ON
/
OFF
button. The unit will first perform a lamp test.
After the test, the alternator charging indication lamp and the
engine oil pressure lamp will light up.
2. Press the
START
button and hold until the engine fires. The
alternator charging indication lamp and the engine oil pressure
lamp will extinguish when the alternator supplies power and the
oil pressure has built up.
Notes:
1. The start prevention switch (S18) prevents the engine from starting
as long as the pressure in the vessel exceeds 1.6 bar.
2. To restart, push the on/off button first.
L
OADING
1. To select automatic load, press the
LOAD
button after the engine
has started (before the warming up indicator light H13
extinguishes). The compressor will start loading when the
engine has warmed up (minimum 30 sec, maximum 5 min).
2. To select manual load, press the
LOAD
button after the engine has
warmed up (after the warming up indicator light H13
extinguishes). The compressor will load immediately. When
pressing the
LOAD
button again, the compressor will run in no
load condition.
D
URING OPERATION
Following checks should be carried out regularly:
1. Check the engine oil pressure (P2), the coolant temperature (P4)
and all lamps for normal readings.
Avoid to let the engine run out of fuel. If it happened,
priming will speed up the starting.
2. Check the adjustment of the regulating valve, i.e. whether the
valve starts decelerating the engine when reaching the preset
working pressure in the air receiver.
3. Check the air outlet temperature (TG) of the compressor
element. Close the door after checking.
S
TOPPING
1. Close the air outlet valve(s).
2. Press the
ON
/
OFF
button. The engine will stop after a 30 seconds
cool down period.
!
!
Summary of Contents for XRVS455 Md
Page 2: ...2 XRVS455 Md ...
Page 26: ...26 XRVS455 Md ...