- 72 -
TOPPING UP AFTER LIMITED QUANTITY DRAINING FROM THE COOLING SYSTEM
The quantity of PARCOOL EG Concentrate to be topped up after draining a calculated volume from the cooling system, can be estimated with the following formula and/
or graph:
Corrections concentrate in measured system towards 50% volume by using PARCOOL EG Concentrate
80
33
33
33
17
67
80
67
20
50-
100-
=
=
*
/
=
Example:
Total volume coolant =
Measured concentration =
In case of expansion tank at normal level, this quantity is to
be drained from the cooling system.
1. Refractometer indication -20° C (33%)
2. Refractometer indication -22° C
3. Refractometer indication -25° C
4. Refractometer indication -30° C
5. Refractometer indication -36° C
Liter
Vol %
Liter PARCOOL EG Concentrate
PN: 1604 8159 00
4
8
12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 76 80 84
0,0
2,5
5,0
7,5
10,0
12,5
15,0
17,5
20,0
22,5
25,0
1
2
3
4
5
Engine coolant capacity (liter)
Top-up volume PARCOOL EG Concentrate with drainage
Top-up volume (lite
r)
Summary of Contents for XAHS 447 Cd S3A APP
Page 2: ......
Page 24: ... 24 SH 03 ENGINE CIRCUIT 1 2 3 5 9 8 7 6 G 4 10 A B C D E F 9822 0963 49 ...
Page 25: ... 25 SH 04 CONTROL MODULE 1 2 3 5 9 8 7 6 4 10 A B C D 9822 0963 49 ...
Page 26: ... 26 SH 05 COMPRESSOR CIRCUIT 1 2 3 5 9 8 7 6 G 4 10 A B C D E F 9822 0963 49 ...
Page 27: ... 27 SH 06 OPTIONAL EQUIPMENT 1 2 3 5 9 8 7 6 G 4 10 A B C D E F 9822 0963 49 ...
Page 28: ... 28 SH 07 OPTIONAL EQUIPMENT 1 2 3 5 9 8 7 6 4 10 A B C D E 9822 0963 49 ...
Page 110: ... 110 Notes ...
Page 111: ......
Page 112: ......