60
Instruction Manual
Generator type
DDG 110V
DDG IT 230V -
3 ph - 6kVA
DDG IT 230/400V -
3 ph - 6kVA
(XAS 47 DDG -
XAS 90 DD7G / DDG IT)
(XAS 47 DDG -
XAS 90 DD7G / DDG IT)
(XAS 47 DDG -
XAS 90 DD7G / DDG IT)
Designation
Unit
Value
Value
Value
Alternator
1. Standard
IEC 34-1
IEC 34-1
IEC 34-1
2. Make
MECC ALTE
MECC ALTE
MECC ALTE
3. Model
MR-1 -180/2
TR-1 -160/2
TR-1 -160/2
4. Rated output
kVA
6
6
6
5. Degree of protection
IP
23
23
23
6. Insulation -
stator
class
H
H
H
- rotor
class
H
H
H
7. Number of phases
1
3
3
8. Number of leads
4
6
6
Electrical power circuit
1. Rated continuous active power
COP
kW
5.5
4.8
4.8
2. Rated power factor (lagging)
1
0.8
0.8
3. Rated continuous apparent power 1 ph
COP
kVA
5.5
4
4
4. Rated voltage 1ph
line to line
V
110
230
230
5. Rated current 1ph
A
50
16
16
6. Frequency droop
%
< 5
< 5
< 5
7. Rated continuous apparent power 3 ph
COP
kVA
-
6
6
8. Rated voltage 3ph
line to line
V
-
230
400
9. Rated current 3ph
A
-
15
8.7
Circuit breaker
1. Number of poles
2
3
4
2. Rated current
In
1ph
A
50
In
1ph/3ph
A
16/16
16/10
3. Thermal release
It
1ph
A
50
It
1ph/3ph
A
16/16
16/10
4. Magnetic release
Im
A
3..5 In
3..5 In
3..5 In
Fault current protection
Insulation resistance
kOhm
10-80
10-80
Residual current release
Idn
A
0.03
Summary of Contents for XAHS 37 DD