General information
EC DECLARATION OF CONFORMITY
We, Atlas Copco Industrial Technique AB, S-105
23 STOCKHOLM SWEDEN declare under our sole
responsibility that our product (with type and serial
number, see front page) and in combination with our
accessories, to which this declaration relates is in
conformity with the appropriate standard(s):
ISO 11148-4
and in accordance with the following directive(s):
2006/42/EC
Technical file available from:
Quality Manager, Atlas Copco Industrial Technique,
Stockholm, Sweden
Stockholm, 1 July 2012
Tobias Hahn, Managing Director
Signature of issuer
Installation
Installation
i
2
1
j
1
2
5000070
6—7 bar =
600—700 kPa
1/4" BSP
10 mm (3/8 ")
1/2"
5000110
• Install chisel (j) and chisel retainer (i), see figure.
• Before use – Put a few drops of air tool oil through
the air inlet.
• Connect the machine to the air line according to
figure. If a quick coupling is used, it should be
separated from the machine by a whip hose (length
0.5 m).
• The compressed air should be free from water and
dirt as far as possible.
The installation of an Atlas Copco filter/regulat-
or/lubricator air preparation set is recommended
to ensure a high quality air supply to the machine.
For lubrication, only use high quality air tool oils.
Air quality
• For optimum performance and maximum machine
life we recommend the use of compressed air with
a maximum dew point of +10°C. We also recom-
mend the installation of an Atlas Copco refrigera-
tion-type air dryer.
• Use a separate air filter of type Atlas Copco FIL.
This filter removes solid particles larger than 15
microns and also removes more than 90 % of li-
quid water. The filter must be installed as close
as possible to the machine/equipment and prior
to any other air preparation unit such as REG or
DIM (please see Air Line Accessories in our main
catalogue). Blow out the hose before connecting.
Models which need air lubrication:
• The compressed air must contain a small quantity
of oil.
We strongly recommend that you install an Atlas
Copco oil-fog lubricator (DIM). This should be
set according to air consumption by the air line
tool according to the following formula:
L
= Air consumption (litre/s).
(May be found in our sales literature).
D
= Number of drops per min (1 drop = 15 mm
3
)
5
© Atlas Copco Industrial Technique AB - 9836 5546 00
Safety and operating instructions
EN
RRF 31