- 105 -
Note 18:AMP 133544-4
Shrinkable sleeve to be attached as in
drawing.
Wall thickness: min. 1 mm.
Wires may be devided over two terminals if
necessary.
1: Braiding
2: Insulated wires
3: Terminal
4: Non-insulated wires
5: Sleeve
Note 18a: The colour of the shrinkable
sleeve should be red
Note 18b: The colour of the shrinkable
sleeve should be blue
Note 19:Connector: Deutsch DT 06-2S
Terminals:
Deutsch 0462-201-16141
Wedge:
Deutsch W 2S
Note 21:This part of the harness should be resistant
to temperatures up to 105 °C.
Note 22:Wire insulation should be resistant to oil,
fuel and coolant.
Note 27:All wire type H05V-K/H07V-K according
to AC standard 0995 2000 00 unless
specified otherwise
Note 30:Connector: Deutsch DT 04-3P
Terminals:
Deutsch 0460-202-16141
Secondary lock:
Deutsch W3P
Note 31:Twisted cables 3 turns each 100 mm
Note 32:Connector: Deutsch DT 06-3S
Terminals:
Deutsch 0462-201-16141
Secondary lock:
Deutsch W3S-1939
Note 33:Connector: Deutsch DT 04-3P-P006
Secondary lock:
Deutsch W3P-1939
Plug for note 32
Note 34:Connector: Deutsch HD36-24-31SE-059
Terminals:
Deutsch 1062-16-0122
Unused cavities to be sealed with:
Deutsch HD10-114017
Note 40:Connector body:
Packard Electric 12065298
Terminals:
Packard Electric 12048074
Wire Seals: Packard Electric 12089678
Secondary lock:
Packard Electric 12066176
Note 41:Relay socket
Housing:
E-T-A R20-4B5-0 + BS-01
Faston:
6,3 x 0,8
Note 51:Protection cap: 1612 0846 00 (or equal)
ORIENTATION AS STATED BELOW
Harness to be fixed on the protection cap.
Rubber cap dimensioned according to cable
section and ring terminal diameter.
Note 52:Rubber cap mounted over eye terminal.
Use nylon strap to prevent rubber cap from
falling off.
Note 53:Relay socket
Housing:
Bosch 3 334 485 008
Faston:
AMP 5-160446-2
Faston:
AMP 160913-4
Note 54:Terminal provided with a red shrinkable
sleeve
1
2
3
4
5
Terminal A
Terminal B
Group 1
3
splice 952
grey
4
splice 953
purple
Group 2
191
splice 952
grey
194
splice 953
purple
Group 3
104
splice 952
grey
105
splice 953
purple