- 76 -
7.4
Compressor control module trouble shooting
7.4.1
Process information
While the compressor is running, the operator can take a brief look at all the incoming compressor and engine data, by pressing the Process Info button.
This can be very useful for trouble shooting over the phone.
7.4.2
Fault codes
There are several parameters that are continuously watched.
When one of these parameters exceeds its specified limit the compressor will react depending the present status of the control box.
Alarm code
Alarm text
Fail class
Trigger
1231
FUEL FILL CHECK
Warning
PC
1503
INITIAL OVERHAUL REQUIRED
Warning
PC
1522
MINOR OVERHAUL WITHIN ** H
Warning
PC
1523
MINOR OVERHAUL WITHIN ** D
Warning
PC
1524
MINOR OVERHAUL REQUIRED
Warning
PC
1552
MAJOR OVERHAUL WITHIN ** H
Warning
PC
1553
MAJOR OVERHAUL WITHIN ** D
Warning
PC
1554
MAJOR OVERHAUL REQUIRED
Warning
PC
2000
EMERGENCY STOP INPUT
Shutdown
PC
2040
REMOTE EMERGENCY STOP
Shutdown
PC
2070
COOLANT LEVEL LOW WARNING
Warning
PC
2080
COOLANT LEVEL LOW SHUTDOWN
Shutdown
PC
2090
∆
P AIRFILTERS HIGH
Warning
PC
2100
NO PROJECTFILE DOWNLOADED
Warning
PC
3000
FUEL LEVEL LOW WARNING
Warning
PC
3010
FUEL LEVEL LOW SHUTDOWN
Controlled Stop
PC
3020
FUEL LEVEL SENSOR CIRCUIT
Warning
PC
3150
AIR DISCHARGE WARNING
Warning
PC
3160
AIR DISCHARGE SHUTDOWN
Shutdown
PC
3170
AIR DISCHARGE PRESSURE SENSOR CIRCUIT
Warning
PC